author | version | line-number | content |
---|---|---|---|
1 | (% class="box infomessage" %) | ||
2 | ((( | ||
3 | BMS Main 2.1 firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 2\.1.4\. Firmware update.WebHome]]. | ||
4 | ))) | ||
5 | |||
6 | = v1.70.2 = | ||
7 | |||
8 | [[BMS_Main_2.1_v1.70.2.srec>>FileManager.BMS_Main_2\.1_v1\.70\.2\.srec]] | ||
9 | |||
10 | == Improvements == | ||
11 | |||
12 | * new parameter setting a delay before measuring battery current during precharge (see the "Cells - Discharging control" section) | ||
13 | * new counter of retry attempts showing the communication problems with BMS Logic devices (see the "Logic/Cell - Overview" section) | ||
14 | * new flag to keep the precharging contactor closed until the precharging process is finished (in this case the "Precharge error" will not occur; see the "Cells - Discharging control" section) | ||
15 | * new flags that force only positive and negative currents to be used to determine open circuit voltages to control the "Ready to charge" and "Ready to discharge" signals respectively | ||
16 | |||
17 | == Fixes == | ||
18 | |||
19 | * resolving the issue of not being able to send log files to a remove FTP server due to a change in the file name format (v1.70.0) | ||
20 | * increased number of retries when sending commands to BMS Logic devices, which reduces the number of false offline event detections | ||
21 | |||
22 | = v1.70.1 = | ||
23 | |||
24 | [[BMS_Main_2.1_v1.70.1.srec>>FileManager.BMS_Main_2\.1_v1\.70\.1\.srec]] | ||
25 | |||
26 | == Improvements == | ||
27 | |||
28 | * new assignments "Low SOC" and "High charging current" for relays | ||
29 | |||
30 | == Fixes == | ||
31 | |||
32 | * resolving the issue of ill-considered reduction of the battery SOC level when the cell voltage is close to the level corresponding to SOC=0% (due to the flow of a large discharge current leading to the high voltage drop on the cells) | ||
33 | |||
34 | = v1.70.0 = | ||
35 | |||
36 | [[BMS_Main_2.1_v1.70.0.srec>>FileManager.BMS_Main_2\.1_v1\.70\.0\.srec]] | ||
37 | |||
38 | == Features == | ||
39 | |||
40 | * new parameters allowing to set different delays for battery discharge mode to detect the overcurrent error (see the "Protections - Overcurrent protection" section) | ||
41 | * new flag that sets whether the BMS should wait for confirmation messages from the Combilift truck to start charging or not (see the "External equipment - Combilift truck" section) | ||
42 | |||
43 | == Fixes == | ||
44 | |||
45 | * optimization of the logging process, minimizing the time to open the next log file if the current one is full | ||
46 | |||
47 | = v1.69.1 = | ||
48 | |||
49 | [[BMS_Main_2.1_v1.69.1.srec>>FileManager.BMS_Main_2\.1_v1\.69\.1\.srec]] | ||
50 | |||
51 | == Fixes == | ||
52 | |||
53 | * check the HYG and Combilift confirmation flags only if the truck offline error is not set | ||
54 | * small internal fixes | ||
55 | |||
56 | = v1.69.0 = | ||
57 | |||
58 | [[BMS_Main_2.1_v1.69.0.srec>>FileManager.BMS_Main_2\.1_v1\.69\.0\.srec]] | ||
59 | |||
60 | == Features == | ||
61 | |||
62 | * new parameter for setting the condition for starting balancing: automatically (regardless of the command) or on the balancing request (see the "Cells - Cell balancing" section) | ||
63 | * new option to start balancing if the cell voltage exceeds the "Voltage for forced balancing" value (see the "Cells - Cell balancing" section) | ||
64 | * new assignment "Balancing request" for the discrete inputs (see the "Signals - Input signals" section) | ||
65 | * new Max-Min algorithm for calculating the final battery SOC in the "Cells - SOC estimation" section | ||
66 | * new algorithms "Automatic" and "On command" for the main contactor (see the "Cells - Main contactor" section) | ||
67 | * new assignment "Close Main contactor" for the discrete inputs to close the main contactor by a command | ||
68 | * new assignment "Close External 1" for the discrete inputs (see the "Signals - Input signals" section) | ||
69 | * new assignment "External 1" for the discrete outputs and relays (see the "Signals - Output signals" section). The "External 1" output is directly controlled by the "Close External 1" command. | ||
70 | * new "Precharge error" flag that is set when precharging cannot be completed | ||
71 | * new flags in the "Protections - Undervoltage protection" and "Protections - Overvoltage protection" sections which allow using the calculated open circuit cell voltage instead of the actual voltage to detect the "Undervoltage" and "Overvoltage" errors, respectively | ||
72 | * ability to check the "Ready to charge" and "Ready to discharge" signals to control the charging and discharging contactors (see the "Cells - Charging control" and "Cells - Discharging control" sections) | ||
73 | |||
74 | == Improvements == | ||
75 | |||
76 | * ignoring the "Need acknowledge" flag when generating Modbus input register 0x2128 ("Error") | ||
77 | * explicit flags to enable the use of the charging current limit for fast and/or normal charging when using the CCS Fast charge controller (see the "External equipment - CCS Fast charge controller" section) | ||
78 | * improving resistance calculation | ||
79 | |||
80 | == Fixes == | ||
81 | |||
82 | * resolving the issue where the "Need acknowledge" signal is not set if any of the device errors are not acknowledged in the error journal | ||
83 | * using the calculated open circuit voltage to set/clear the "Ready to charge" and "Ready to discharge" signals | ||
84 | |||
85 | = v1.68.0 = | ||
86 | |||
87 | [[BMS_Main_2.1_v1.68.0.srec>>FileManager.BMS_Main_2\.1_v1\.68\.0\.srec]] | ||
88 | |||
89 | == Features == | ||
90 | |||
91 | - support for charge/discharge cycling using XD Discharger (see the sections "External equipment - Battery cycling" and "External equipment - XD Discharger (cycling)") | ||
92 | |||
93 | = v1.67.0 = | ||
94 | |||
95 | [[BMS_Main_2.1_v1.67.0.srec>>FileManager.BMS_Main_2\.1_v1\.67\.0\.srec]] | ||
96 | |||
97 | == Features == | ||
98 | |||
99 | * new additional heater controller (see the "Protections - Heater (AUX) control" section), which generates the "Heater (AUX)" signal, which can be assigned to a discrete output or relay | ||
100 | |||
101 | == Improvements == | ||
102 | |||
103 | * new balancing strategy that attempts to keep the temperature of BMS Logic devices below a set value by discharging cells with higher voltages first than others (see the "Cells - Cell balancing" section) | ||
104 | |||
105 | = v1.66.1 = | ||
106 | |||
107 | [[BMS_Main_2.1_v1.66.1.srec>>FileManager.BMS_Main_2\.1_v1\.66\.1\.srec]] | ||
108 | |||
109 | == Improvements == | ||
110 | |||
111 | * closing all TCP connections over Ethernet if the interface link is down | ||
112 | |||
113 | = v1.66.0 = | ||
114 | |||
115 | [[BMS_Main_2.1_v1.66.0.srec>>FileManager.BMS_Main_2\.1_v1\.66\.0\.srec]] | ||
116 | |||
117 | == Features == | ||
118 | |||
119 | * support for the insulation monitoring device BMS IMD (see the section "External equipment - BMS IMD device") | ||
120 | |||
121 | == Improvements == | ||
122 | |||
123 | * new parameters for switching off the Discharging (AUX) relay when the cell voltage is too low (see the "Cells - Discharging (AUX) control" section) |