Wiki source code of BMS Main 2.1
Show last authors
| author | version | line-number | content |
|---|---|---|---|
| 1 | (% class="box infomessage" %) | ||
| 2 | ((( | ||
| 3 | BMS Main 2.1 firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 2\.1.4\. Firmware update.WebHome]]. | ||
| 4 | ))) | ||
| 5 | |||
| 6 | = v1.70.2 = | ||
| 7 | |||
| 8 | [[BMS_Main_2.1_v1.70.2.srec>>FileManager.BMS_Main_2\.1_v1\.70\.2\.srec]] | ||
| 9 | |||
| 10 | == Improvements == | ||
| 11 | |||
| 12 | * new parameter setting a delay before measuring battery current during precharge (see the "Cells - Discharging control" section) | ||
| 13 | * new counter of retry attempts showing the communication problems with BMS Logic devices (see the "Logic/Cell - Overview" section) | ||
| 14 | * new flag to keep the precharging contactor closed until the precharging process is finished (in this case the "Precharge error" will not occur; see the "Cells - Discharging control" section) | ||
| 15 | * new flags that force only positive and negative currents to be used to determine open circuit voltages to control the "Ready to charge" and "Ready to discharge" signals respectively | ||
| 16 | |||
| 17 | == Fixes == | ||
| 18 | |||
| 19 | * resolving the issue of not being able to send log files to a remove FTP server due to a change in the file name format (v1.70.0) | ||
| 20 | * increased number of retries when sending commands to BMS Logic devices, which reduces the number of false offline event detections | ||
| 21 | |||
| 22 | = v1.70.1 = | ||
| 23 | |||
| 24 | [[BMS_Main_2.1_v1.70.1.srec>>FileManager.BMS_Main_2\.1_v1\.70\.1\.srec]] | ||
| 25 | |||
| 26 | == Improvements == | ||
| 27 | |||
| 28 | * new assignments "Low SOC" and "High charging current" for relays | ||
| 29 | |||
| 30 | == Fixes == | ||
| 31 | |||
| 32 | * resolving the issue of ill-considered reduction of the battery SOC level when the cell voltage is close to the level corresponding to SOC=0% (due to the flow of a large discharge current leading to the high voltage drop on the cells) | ||
| 33 | |||
| 34 | = v1.70.0 = | ||
| 35 | |||
| 36 | [[BMS_Main_2.1_v1.70.0.srec>>FileManager.BMS_Main_2\.1_v1\.70\.0\.srec]] | ||
| 37 | |||
| 38 | == Features == | ||
| 39 | |||
| 40 | * new parameters allowing to set different delays for battery discharge mode to detect the overcurrent error (see the "Protections - Overcurrent protection" section) | ||
| 41 | * new flag that sets whether the BMS should wait for confirmation messages from the Combilift truck to start charging or not (see the "External equipment - Combilift truck" section) | ||
| 42 | |||
| 43 | == Fixes == | ||
| 44 | |||
| 45 | * optimization of the logging process, minimizing the time to open the next log file if the current one is full | ||
| 46 | |||
| 47 | = v1.69.1 = | ||
| 48 | |||
| 49 | [[BMS_Main_2.1_v1.69.1.srec>>FileManager.BMS_Main_2\.1_v1\.69\.1\.srec]] | ||
| 50 | |||
| 51 | == Fixes == | ||
| 52 | |||
| 53 | * check the HYG and Combilift confirmation flags only if the truck offline error is not set | ||
| 54 | * small internal fixes | ||
| 55 | |||
| 56 | = v1.69.0 = | ||
| 57 | |||
| 58 | [[BMS_Main_2.1_v1.69.0.srec>>FileManager.BMS_Main_2\.1_v1\.69\.0\.srec]] | ||
| 59 | |||
| 60 | == Features == | ||
| 61 | |||
| 62 | * new parameter for setting the condition for starting balancing: automatically (regardless of the command) or on the balancing request (see the "Cells - Cell balancing" section) | ||
| 63 | * new option to start balancing if the cell voltage exceeds the "Voltage for forced balancing" value (see the "Cells - Cell balancing" section) | ||
| 64 | * new assignment "Balancing request" for the discrete inputs (see the "Signals - Input signals" section) | ||
| 65 | * new Max-Min algorithm for calculating the final battery SOC in the "Cells - SOC estimation" section | ||
| 66 | * new algorithms "Automatic" and "On command" for the main contactor (see the "Cells - Main contactor" section) | ||
| 67 | * new assignment "Close Main contactor" for the discrete inputs to close the main contactor by a command | ||
| 68 | * new assignment "Close External 1" for the discrete inputs (see the "Signals - Input signals" section) | ||
| 69 | * new assignment "External 1" for the discrete outputs and relays (see the "Signals - Output signals" section). The "External 1" output is directly controlled by the "Close External 1" command. | ||
| 70 | * new "Precharge error" flag that is set when precharging cannot be completed | ||
| 71 | * new flags in the "Protections - Undervoltage protection" and "Protections - Overvoltage protection" sections which allow using the calculated open circuit cell voltage instead of the actual voltage to detect the "Undervoltage" and "Overvoltage" errors, respectively | ||
| 72 | * ability to check the "Ready to charge" and "Ready to discharge" signals to control the charging and discharging contactors (see the "Cells - Charging control" and "Cells - Discharging control" sections) | ||
| 73 | |||
| 74 | == Improvements == | ||
| 75 | |||
| 76 | * ignoring the "Need acknowledge" flag when generating Modbus input register 0x2128 ("Error") | ||
| 77 | * explicit flags to enable the use of the charging current limit for fast and/or normal charging when using the CCS Fast charge controller (see the "External equipment - CCS Fast charge controller" section) | ||
| 78 | * improving resistance calculation | ||
| 79 | |||
| 80 | == Fixes == | ||
| 81 | |||
| 82 | * resolving the issue where the "Need acknowledge" signal is not set if any of the device errors are not acknowledged in the error journal | ||
| 83 | * using the calculated open circuit voltage to set/clear the "Ready to charge" and "Ready to discharge" signals | ||
| 84 | |||
| 85 | = v1.68.0 = | ||
| 86 | |||
| 87 | [[BMS_Main_2.1_v1.68.0.srec>>FileManager.BMS_Main_2\.1_v1\.68\.0\.srec]] | ||
| 88 | |||
| 89 | == Features == | ||
| 90 | |||
| 91 | - support for charge/discharge cycling using XD Discharger (see the sections "External equipment - Battery cycling" and "External equipment - XD Discharger (cycling)") | ||
| 92 | |||
| 93 | = v1.67.0 = | ||
| 94 | |||
| 95 | [[BMS_Main_2.1_v1.67.0.srec>>FileManager.BMS_Main_2\.1_v1\.67\.0\.srec]] | ||
| 96 | |||
| 97 | == Features == | ||
| 98 | |||
| 99 | * new additional heater controller (see the "Protections - Heater (AUX) control" section), which generates the "Heater (AUX)" signal, which can be assigned to a discrete output or relay | ||
| 100 | |||
| 101 | == Improvements == | ||
| 102 | |||
| 103 | * new balancing strategy that attempts to keep the temperature of BMS Logic devices below a set value by discharging cells with higher voltages first than others (see the "Cells - Cell balancing" section) | ||
| 104 | |||
| 105 | = v1.66.1 = | ||
| 106 | |||
| 107 | [[BMS_Main_2.1_v1.66.1.srec>>FileManager.BMS_Main_2\.1_v1\.66\.1\.srec]] | ||
| 108 | |||
| 109 | == Improvements == | ||
| 110 | |||
| 111 | * closing all TCP connections over Ethernet if the interface link is down | ||
| 112 | |||
| 113 | = v1.66.0 = | ||
| 114 | |||
| 115 | [[BMS_Main_2.1_v1.66.0.srec>>FileManager.BMS_Main_2\.1_v1\.66\.0\.srec]] | ||
| 116 | |||
| 117 | == Features == | ||
| 118 | |||
| 119 | * support for the insulation monitoring device BMS IMD (see the section "External equipment - BMS IMD device") | ||
| 120 | |||
| 121 | == Improvements == | ||
| 122 | |||
| 123 | * new parameters for switching off the Discharging (AUX) relay when the cell voltage is too low (see the "Cells - Discharging (AUX) control" section) |