... ... @@ -1,82 +1,5 @@
1 -(% class="box infomessage" %)
2 -(((
3 -BMS Main 2.1 firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 2\.1.4\. Firmware update.WebHome]].
4 -)))
1 +v1.66.0
5 5  
6 -= v1.69.1 =
7 -
8 -[[BMS_Main_2.1_v1.69.1.srec>>FileManager.BMS_Main_2\.1_v1\.69\.1\.srec]]
9 -
10 -== Fixes ==
11 -
12 -* check the HYG and Combilift confirmation flags only if the truck offline error is not set
13 -* small internal fixes
14 -
15 -= v1.69.0 =
16 -
17 -[[BMS_Main_2.1_v1.69.0.srec>>FileManager.BMS_Main_2\.1_v1\.69\.0\.srec]]
18 -
19 -== Features ==
20 -
21 -* new parameter for setting the condition for starting balancing: automatically (regardless of the command) or on the balancing request (see the "Cells - Cell balancing" section)
22 -* new option to start balancing if the cell voltage exceeds the "Voltage for forced balancing" value (see the "Cells - Cell balancing" section)
23 -* new assignment "Balancing request" for the discrete inputs (see the "Signals - Input signals" section)
24 -* new Max-Min algorithm for calculating the final battery SOC in the "Cells - SOC estimation" section
25 -* new algorithms "Automatic" and "On command" for the main contactor (see the "Cells - Main contactor" section)
26 -* new assignment "Close Main contactor" for the discrete inputs to close the main contactor by a command
27 -* new assignment "Close External 1" for the discrete inputs (see the "Signals - Input signals" section)
28 -* new assignment "External 1" for the discrete outputs and relays (see the "Signals - Output signals" section). The "External 1" output is directly controlled by the "Close External 1" command.
29 -* new "Precharge error" flag that is set when precharging cannot be completed
30 -* new flags in the "Protections - Undervoltage protection" and "Protections - Overvoltage protection" sections which allow using the calculated open circuit cell voltage instead of the actual voltage to detect the "Undervoltage" and "Overvoltage" errors, respectively
31 -* ability to check the "Ready to charge" and "Ready to discharge" signals to control the charging and discharging contactors (see the "Cells - Charging control" and "Cells - Discharging control" sections)
32 -
33 -== Improvements ==
34 -
35 -* ignoring the "Need acknowledge" flag when generating Modbus input register 0x2128 ("Error")
36 -* explicit flags to enable the use of the charging current limit for fast and/or normal charging when using the CCS Fast charge controller (see the "External equipment - CCS Fast charge controller" section)
37 -* improving resistance calculation
38 -
39 -== Fixes ==
40 -
41 -* resolving the issue where the "Need acknowledge" signal is not set if any of the device errors are not acknowledged in the error journal
42 -* using the calculated open circuit voltage to set/clear the "Ready to charge" and "Ready to discharge" signals
43 -
44 -= v1.68.0 =
45 -
46 -[[BMS_Main_2.1_v1.68.0.srec>>FileManager.BMS_Main_2\.1_v1\.68\.0\.srec]]
47 -
48 -== Features ==
49 -
50 -- support for charge/discharge cycling using XD Discharger (see the sections "External equipment - Battery cycling" and "External equipment - XD Discharger (cycling)")
51 -
52 -= v1.67.0 =
53 -
54 -[[BMS_Main_2.1_v1.67.0.srec>>FileManager.BMS_Main_2\.1_v1\.67\.0\.srec]]
55 -
56 -== Features ==
57 -
58 -* new additional heater controller (see the "Protections - Heater (AUX) control" section), which generates the "Heater (AUX)" signal, which can be assigned to a discrete output or relay
59 -
60 -== Improvements ==
61 -
62 -* new balancing strategy that attempts to keep the temperature of BMS Logic devices below a set value by discharging cells with higher voltages first than others (see the "Cells - Cell balancing" section)
63 -
64 -= v1.66.1 =
65 -
66 -[[BMS_Main_2.1_v1.66.1.srec>>FileManager.BMS_Main_2\.1_v1\.66\.1\.srec]]
67 -
68 -== Improvements ==
69 -
70 -* closing all TCP connections over Ethernet if the interface link is down
71 -
72 -= v1.66.0 =
73 -
74 74  [[BMS_Main_2.1_v1.66.0.srec>>FileManager.BMS_Main_2\.1_v1\.66\.0\.srec]]
75 75  
76 -== Features ==
77 -
78 -* support for the insulation monitoring device BMS IMD (see the section "External equipment - BMS IMD device")
79 -
80 -== Improvements ==
81 -
82 -* new parameters for switching off the Discharging (AUX) relay when the cell voltage is too low (see the "Cells - Discharging (AUX) control" section)
5 +