Changes for page BMS Main 2.1

Last modified by Admin on 2025/04/14 10:35

From version 8.1
edited by Admin
on 2025/01/21 08:01
Change comment: There is no comment for this version
To version 1.2
edited by Admin
on 2024/11/22 09:05
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,73 +1,5 @@
1 -(% class="box infomessage" %)
2 -(((
3 -BMS Main 2.1 firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 2\.1.4\. Firmware update.WebHome]].
4 -)))
1 +v1.66.0
5 5  
6 -= v1.69.0 =
7 -
8 -[[BMS_Main_2.1_v1.69.0.srec>>FileManager.BMS_Main_2\.1_v1\.69\.0\.srec]]
9 -
10 -== Features ==
11 -
12 -* new parameter for setting the condition for starting balancing: automatically (regardless of the command) or on the balancing request (see the "Cells - Cell balancing" section)
13 -* new option to start balancing if the cell voltage exceeds the "Voltage for forced balancing" value (see the "Cells - Cell balancing" section)
14 -* new assignment "Balancing request" for the discrete inputs (see the "Signals - Input signals" section)
15 -* new Max-Min algorithm for calculating the final battery SOC in the "Cells - SOC estimation" section
16 -* new algorithms "Automatic" and "On command" for the main contactor (see the "Cells - Main contactor" section)
17 -* new assignment "Close Main contactor" for the discrete inputs to close the main contactor by a command
18 -* new assignment "Close External 1" for the discrete inputs (see the "Signals - Input signals" section)
19 -* new assignment "External 1" for the discrete outputs and relays (see the "Signals - Output signals" section). The "External 1" output is directly controlled by the "Close External 1" command.
20 -* new "Precharge error" flag that is set when precharging cannot be completed
21 -* new flags in the "Protections - Undervoltage protection" and "Protections - Overvoltage protection" sections which allow using the calculated open circuit cell voltage instead of the actual voltage to detect the "Undervoltage" and "Overvoltage" errors, respectively
22 -* ability to check the "Ready to charge" and "Ready to discharge" signals to control the charging and discharging contactors (see the "Cells - Charging control" and "Cells - Discharging control" sections)
23 -
24 -== Improvements ==
25 -
26 -* ignoring the "Need acknowledge" flag when generating Modbus input register 0x2128 ("Error")
27 -* explicit flags to enable the use of the charging current limit for fast and/or normal charging when using the CCS Fast charge controller (see the "External equipment - CCS Fast charge controller" section)
28 -* improving resistance calculation
29 -
30 -== Fixes ==
31 -
32 -* resolving the issue where the "Need acknowledge" signal is not set if any of the device errors are not acknowledged in the error journal
33 -* using the calculated open circuit voltage to set/clear the "Ready to charge" and "Ready to discharge" signals
34 -
35 -= v1.68.0 =
36 -
37 -[[BMS_Main_2.1_v1.68.0.srec>>FileManager.BMS_Main_2\.1_v1\.68\.0\.srec]]
38 -
39 -== Features ==
40 -
41 -- support for charge/discharge cycling using XD Discharger (see the sections "External equipment - Battery cycling" and "External equipment - XD Discharger (cycling)")
42 -
43 -= v1.67.0 =
44 -
45 -[[BMS_Main_2.1_v1.67.0.srec>>FileManager.BMS_Main_2\.1_v1\.67\.0\.srec]]
46 -
47 -== Features ==
48 -
49 -* new additional heater controller (see the "Protections - Heater (AUX) control" section), which generates the "Heater (AUX)" signal, which can be assigned to a discrete output or relay
50 -
51 -== Improvements ==
52 -
53 -* new balancing strategy that attempts to keep the temperature of BMS Logic devices below a set value by discharging cells with higher voltages first than others (see the "Cells - Cell balancing" section)
54 -
55 -= v1.66.1 =
56 -
57 -[[BMS_Main_2.1_v1.66.1.srec>>FileManager.BMS_Main_2\.1_v1\.66\.1\.srec]]
58 -
59 -== Improvements ==
60 -
61 -* closing all TCP connections over Ethernet if the interface link is down
62 -
63 -= v1.66.0 =
64 -
65 65  [[BMS_Main_2.1_v1.66.0.srec>>FileManager.BMS_Main_2\.1_v1\.66\.0\.srec]]
66 66  
67 -== Features ==
68 -
69 -* support for the insulation monitoring device BMS IMD (see the section "External equipment - BMS IMD device")
70 -
71 -== Improvements ==
72 -
73 -* new parameters for switching off the Discharging (AUX) relay when the cell voltage is too low (see the "Cells - Discharging (AUX) control" section)
5 +