Changes for page BMS Main 2.1
Last modified by Admin on 2025/04/14 10:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,6 +1,59 @@ 1 -(% class="wikigeneratedid" %) 1 +(% class="box infomessage" %) 2 +((( 2 2 BMS Main 2.1 firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 2\.1.4\. Firmware update.WebHome]]. 4 +))) 3 3 6 += v1.70.0 = 7 + 8 +[[BMS_Main_2.1_v1.70.0.srec>>FileManager.BMS_Main_2\.1_v1\.70\.0\.srec]] 9 + 10 +== Features == 11 + 12 +* new parameters allowing to set different delays for battery discharge mode to detect the overcurrent error (see the "Protections - Overcurrent protection" section) 13 +* new flag that sets whether the BMS should wait for confirmation messages from the Combilift truck to start charging or not (see the "External equipment - Combilift truck" section) 14 + 15 +== Fixes == 16 + 17 +* optimization of the logging process, minimizing the time to open the next log file if the current one is full 18 + 19 += v1.69.1 = 20 + 21 +[[BMS_Main_2.1_v1.69.1.srec>>FileManager.BMS_Main_2\.1_v1\.69\.1\.srec]] 22 + 23 +== Fixes == 24 + 25 +* check the HYG and Combilift confirmation flags only if the truck offline error is not set 26 +* small internal fixes 27 + 28 += v1.69.0 = 29 + 30 +[[BMS_Main_2.1_v1.69.0.srec>>FileManager.BMS_Main_2\.1_v1\.69\.0\.srec]] 31 + 32 +== Features == 33 + 34 +* new parameter for setting the condition for starting balancing: automatically (regardless of the command) or on the balancing request (see the "Cells - Cell balancing" section) 35 +* new option to start balancing if the cell voltage exceeds the "Voltage for forced balancing" value (see the "Cells - Cell balancing" section) 36 +* new assignment "Balancing request" for the discrete inputs (see the "Signals - Input signals" section) 37 +* new Max-Min algorithm for calculating the final battery SOC in the "Cells - SOC estimation" section 38 +* new algorithms "Automatic" and "On command" for the main contactor (see the "Cells - Main contactor" section) 39 +* new assignment "Close Main contactor" for the discrete inputs to close the main contactor by a command 40 +* new assignment "Close External 1" for the discrete inputs (see the "Signals - Input signals" section) 41 +* new assignment "External 1" for the discrete outputs and relays (see the "Signals - Output signals" section). The "External 1" output is directly controlled by the "Close External 1" command. 42 +* new "Precharge error" flag that is set when precharging cannot be completed 43 +* new flags in the "Protections - Undervoltage protection" and "Protections - Overvoltage protection" sections which allow using the calculated open circuit cell voltage instead of the actual voltage to detect the "Undervoltage" and "Overvoltage" errors, respectively 44 +* ability to check the "Ready to charge" and "Ready to discharge" signals to control the charging and discharging contactors (see the "Cells - Charging control" and "Cells - Discharging control" sections) 45 + 46 +== Improvements == 47 + 48 +* ignoring the "Need acknowledge" flag when generating Modbus input register 0x2128 ("Error") 49 +* explicit flags to enable the use of the charging current limit for fast and/or normal charging when using the CCS Fast charge controller (see the "External equipment - CCS Fast charge controller" section) 50 +* improving resistance calculation 51 + 52 +== Fixes == 53 + 54 +* resolving the issue where the "Need acknowledge" signal is not set if any of the device errors are not acknowledged in the error journal 55 +* using the calculated open circuit voltage to set/clear the "Ready to charge" and "Ready to discharge" signals 56 + 4 4 = v1.68.0 = 5 5 6 6 [[BMS_Main_2.1_v1.68.0.srec>>FileManager.BMS_Main_2\.1_v1\.68\.0\.srec]]