Changes for page BMS Main 2.1
Last modified by Admin on 2025/05/29 14:02
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,6 +1,95 @@ 1 -(% class="wikigeneratedid" %) 1 +(% class="box infomessage" %) 2 +((( 2 2 BMS Main 2.1 firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 2\.1.4\. Firmware update.WebHome]]. 4 +))) 3 3 6 += v1.70.2 = 7 + 8 +[[BMS_Main_2.1_v1.70.2.srec>>FileManager.BMS_Main_2\.1_v1\.70\.2\.srec]] 9 + 10 +== Improvements == 11 + 12 +* new parameter setting a delay before measuring battery current during precharge (see the "Cells - Discharging control" section) 13 +* new counter of retry attempts showing the communication problems with BMS Logic devices (see the "Logic/Cell - Overview" section) 14 +* new flag to keep the precharging contactor closed until the precharging process is finished (in this case the "Precharge error" will not occur; see the "Cells - Discharging control" section) 15 +* new flags that force only positive and negative currents to be used to determine open circuit voltages to control the "Ready to charge" and "Ready to discharge" signals respectively 16 + 17 +== Fixes == 18 + 19 +* resolving the issue of not being able to send log files to a remove FTP server due to a change in the file name format (v1.70.0) 20 +* increased number of retries when sending commands to BMS Logic devices, which reduces the number of false offline event detections 21 + 22 += v1.70.1 = 23 + 24 +[[BMS_Main_2.1_v1.70.1.srec>>FileManager.BMS_Main_2\.1_v1\.70\.1\.srec]] 25 + 26 +== Improvements == 27 + 28 +* new assignments "Low SOC" and "High charging current" for relays 29 + 30 +== Fixes == 31 + 32 +* resolving the issue of ill-considered reduction of the battery SOC level when the cell voltage is close to the level corresponding to SOC=0% (due to the flow of a large discharge current leading to the high voltage drop on the cells) 33 + 34 += v1.70.0 = 35 + 36 +[[BMS_Main_2.1_v1.70.0.srec>>FileManager.BMS_Main_2\.1_v1\.70\.0\.srec]] 37 + 38 +== Features == 39 + 40 +* new parameters allowing to set different delays for battery discharge mode to detect the overcurrent error (see the "Protections - Overcurrent protection" section) 41 +* new flag that sets whether the BMS should wait for confirmation messages from the Combilift truck to start charging or not (see the "External equipment - Combilift truck" section) 42 + 43 +== Fixes == 44 + 45 +* optimization of the logging process, minimizing the time to open the next log file if the current one is full 46 + 47 += v1.69.1 = 48 + 49 +[[BMS_Main_2.1_v1.69.1.srec>>FileManager.BMS_Main_2\.1_v1\.69\.1\.srec]] 50 + 51 +== Fixes == 52 + 53 +* check the HYG and Combilift confirmation flags only if the truck offline error is not set 54 +* small internal fixes 55 + 56 += v1.69.0 = 57 + 58 +[[BMS_Main_2.1_v1.69.0.srec>>FileManager.BMS_Main_2\.1_v1\.69\.0\.srec]] 59 + 60 +== Features == 61 + 62 +* new parameter for setting the condition for starting balancing: automatically (regardless of the command) or on the balancing request (see the "Cells - Cell balancing" section) 63 +* new option to start balancing if the cell voltage exceeds the "Voltage for forced balancing" value (see the "Cells - Cell balancing" section) 64 +* new assignment "Balancing request" for the discrete inputs (see the "Signals - Input signals" section) 65 +* new Max-Min algorithm for calculating the final battery SOC in the "Cells - SOC estimation" section 66 +* new algorithms "Automatic" and "On command" for the main contactor (see the "Cells - Main contactor" section) 67 +* new assignment "Close Main contactor" for the discrete inputs to close the main contactor by a command 68 +* new assignment "Close External 1" for the discrete inputs (see the "Signals - Input signals" section) 69 +* new assignment "External 1" for the discrete outputs and relays (see the "Signals - Output signals" section). The "External 1" output is directly controlled by the "Close External 1" command. 70 +* new "Precharge error" flag that is set when precharging cannot be completed 71 +* new flags in the "Protections - Undervoltage protection" and "Protections - Overvoltage protection" sections which allow using the calculated open circuit cell voltage instead of the actual voltage to detect the "Undervoltage" and "Overvoltage" errors, respectively 72 +* ability to check the "Ready to charge" and "Ready to discharge" signals to control the charging and discharging contactors (see the "Cells - Charging control" and "Cells - Discharging control" sections) 73 + 74 +== Improvements == 75 + 76 +* ignoring the "Need acknowledge" flag when generating Modbus input register 0x2128 ("Error") 77 +* explicit flags to enable the use of the charging current limit for fast and/or normal charging when using the CCS Fast charge controller (see the "External equipment - CCS Fast charge controller" section) 78 +* improving resistance calculation 79 + 80 +== Fixes == 81 + 82 +* resolving the issue where the "Need acknowledge" signal is not set if any of the device errors are not acknowledged in the error journal 83 +* using the calculated open circuit voltage to set/clear the "Ready to charge" and "Ready to discharge" signals 84 + 85 += v1.68.0 = 86 + 87 +[[BMS_Main_2.1_v1.68.0.srec>>FileManager.BMS_Main_2\.1_v1\.68\.0\.srec]] 88 + 89 +== Features == 90 + 91 +- support for charge/discharge cycling using XD Discharger (see the sections "External equipment - Battery cycling" and "External equipment - XD Discharger (cycling)") 92 + 4 4 = v1.67.0 = 5 5 6 6 [[BMS_Main_2.1_v1.67.0.srec>>FileManager.BMS_Main_2\.1_v1\.67\.0\.srec]]