6 += v1.70.2 =
7 +
8 +[[BMS_Main_2.1_v1.70.2.srec>>FileManager.BMS_Main_2\.1_v1\.70\.2\.srec]]
9 +
10 +== Improvements ==
11 +
12 +* new parameter setting a delay before measuring battery current during precharge (see the "Cells - Discharging control" section)
13 +* new counter of retry attempts showing the communication problems with BMS Logic devices (see the "Logic/Cell - Overview" section)
14 +* new flag to keep the precharging contactor closed until the precharging process is finished (in this case the "Precharge error" will not occur; see the "Cells - Discharging control" section)
15 +* new flags that force only positive and negative currents to be used to determine open circuit voltages to control the "Ready to charge" and "Ready to discharge" signals respectively
16 +
17 +== Fixes ==
18 +
19 +* resolving the issue of not being able to send log files to a remove FTP server due to a change in the file name format (v1.70.0)
20 +* increased number of retries when sending commands to BMS Logic devices, which reduces the number of false offline event detections
21 +
22 += v1.70.1 =
23 +
24 +[[BMS_Main_2.1_v1.70.1.srec>>FileManager.BMS_Main_2\.1_v1\.70\.1\.srec]]
25 +
26 +== Improvements ==
27 +
28 +* new assignments "Low SOC" and "High charging current" for relays
29 +
30 +== Fixes ==
31 +
32 +* resolving the issue of ill-considered reduction of the battery SOC level when the cell voltage is close to the level corresponding to SOC=0% (due to the flow of a large discharge current leading to the high voltage drop on the cells)
33 +
34 += v1.70.0 =
35 +
36 +[[BMS_Main_2.1_v1.70.0.srec>>FileManager.BMS_Main_2\.1_v1\.70\.0\.srec]]
37 +
38 +== Features ==
39 +
40 +* new parameters allowing to set different delays for battery discharge mode to detect the overcurrent error (see the "Protections - Overcurrent protection" section)
41 +* new flag that sets whether the BMS should wait for confirmation messages from the Combilift truck to start charging or not (see the "External equipment - Combilift truck" section)
42 +
43 +== Fixes ==
44 +
45 +* optimization of the logging process, minimizing the time to open the next log file if the current one is full
46 +
47 += v1.69.1 =
48 +
49 +[[BMS_Main_2.1_v1.69.1.srec>>FileManager.BMS_Main_2\.1_v1\.69\.1\.srec]]
50 +
51 +== Fixes ==
52 +
53 +* check the HYG and Combilift confirmation flags only if the truck offline error is not set
54 +* small internal fixes
55 +
56 += v1.69.0 =
57 +
58 +[[BMS_Main_2.1_v1.69.0.srec>>FileManager.BMS_Main_2\.1_v1\.69\.0\.srec]]
59 +
60 +== Features ==
61 +
62 +* new parameter for setting the condition for starting balancing: automatically (regardless of the command) or on the balancing request (see the "Cells - Cell balancing" section)
63 +* new option to start balancing if the cell voltage exceeds the "Voltage for forced balancing" value (see the "Cells - Cell balancing" section)
64 +* new assignment "Balancing request" for the discrete inputs (see the "Signals - Input signals" section)
65 +* new Max-Min algorithm for calculating the final battery SOC in the "Cells - SOC estimation" section
66 +* new algorithms "Automatic" and "On command" for the main contactor (see the "Cells - Main contactor" section)
67 +* new assignment "Close Main contactor" for the discrete inputs to close the main contactor by a command
68 +* new assignment "Close External 1" for the discrete inputs (see the "Signals - Input signals" section)
69 +* new assignment "External 1" for the discrete outputs and relays (see the "Signals - Output signals" section). The "External 1" output is directly controlled by the "Close External 1" command.
70 +* new "Precharge error" flag that is set when precharging cannot be completed
71 +* new flags in the "Protections - Undervoltage protection" and "Protections - Overvoltage protection" sections which allow using the calculated open circuit cell voltage instead of the actual voltage to detect the "Undervoltage" and "Overvoltage" errors, respectively
72 +* ability to check the "Ready to charge" and "Ready to discharge" signals to control the charging and discharging contactors (see the "Cells - Charging control" and "Cells - Discharging control" sections)
73 +
74 +== Improvements ==
75 +
76 +* ignoring the "Need acknowledge" flag when generating Modbus input register 0x2128 ("Error")
77 +* explicit flags to enable the use of the charging current limit for fast and/or normal charging when using the CCS Fast charge controller (see the "External equipment - CCS Fast charge controller" section)
78 +* improving resistance calculation
79 +
80 +== Fixes ==
81 +
82 +* resolving the issue where the "Need acknowledge" signal is not set if any of the device errors are not acknowledged in the error journal
83 +* using the calculated open circuit voltage to set/clear the "Ready to charge" and "Ready to discharge" signals
84 +
85 += v1.68.0 =
86 +
87 +[[BMS_Main_2.1_v1.68.0.srec>>FileManager.BMS_Main_2\.1_v1\.68\.0\.srec]]
88 +
89 +== Features ==
90 +
91 +- support for charge/discharge cycling using XD Discharger (see the sections "External equipment - Battery cycling" and "External equipment - XD Discharger (cycling)")
92 +
4 4  = v1.67.0 =
5 5  
6 6  [[BMS_Main_2.1_v1.67.0.srec>>FileManager.BMS_Main_2\.1_v1\.67\.0\.srec]]