Changes for page BMS Main 2.1

Last modified by Admin on 2025/04/14 10:35

From version 4.1
edited by Admin
on 2024/12/11 12:47
Change comment: There is no comment for this version
To version 2.1
edited by Admin
on 2024/11/22 09:06
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,26 +24,3 @@
1 -(% class="wikigeneratedid" %)
2 -BMS Main 2.1 firmware upgrade procedure is described [[here>>doc:Battery management systems.BMS Main 2\.1.4\. Firmware update.WebHome]].
3 -
4 -= v1.67.0 =
5 -
6 -[[BMS_Main_2.1_v1.67.0.srec>>FileManager.BMS_Main_2\.1_v1\.67\.0\.srec]]
7 -
8 -== Features ==
9 -
10 -* new additional heater controller (see the "Protections - Heater (AUX) control" section), which generates the "Heater (AUX)" signal, which can be assigned to a discrete output or relay
11 -
12 -== Improvements ==
13 -
14 -* new balancing strategy that attempts to keep the temperature of BMS Logic devices below a set value by discharging cells with higher voltages first than others (see the "Cells - Cell balancing" section)
15 -
16 -= v1.66.1 =
17 -
18 -[[BMS_Main_2.1_v1.66.1.srec>>FileManager.BMS_Main_2\.1_v1\.66\.1\.srec]]
19 -
20 -== Improvements ==
21 -
22 -* closing all TCP connections over Ethernet if the interface link is down
23 -
24 24  = v1.66.0 =
25 25  
26 26  [[BMS_Main_2.1_v1.66.0.srec>>FileManager.BMS_Main_2\.1_v1\.66\.0\.srec]]