Changes for page BMS Main 2.1

Last modified by Admin on 2025/05/29 14:02

From version 2.1
edited by Admin
on 2024/11/22 09:06
Change comment: There is no comment for this version
To version 7.1
edited by Admin
on 2024/12/25 14:05
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,3 +1,36 @@
1 +(% class="box infomessage" %)
2 +(((
3 +BMS Main 2.1 firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 2\.1.4\. Firmware update.WebHome]].
4 +)))
5 +
6 += v1.68.0 =
7 +
8 +[[BMS_Main_2.1_v1.68.0.srec>>FileManager.BMS_Main_2\.1_v1\.68\.0\.srec]]
9 +
10 +== Features ==
11 +
12 +- support for charge/discharge cycling using XD Discharger (see the sections "External equipment - Battery cycling" and "External equipment - XD Discharger (cycling)")
13 +
14 += v1.67.0 =
15 +
16 +[[BMS_Main_2.1_v1.67.0.srec>>FileManager.BMS_Main_2\.1_v1\.67\.0\.srec]]
17 +
18 +== Features ==
19 +
20 +* new additional heater controller (see the "Protections - Heater (AUX) control" section), which generates the "Heater (AUX)" signal, which can be assigned to a discrete output or relay
21 +
22 +== Improvements ==
23 +
24 +* new balancing strategy that attempts to keep the temperature of BMS Logic devices below a set value by discharging cells with higher voltages first than others (see the "Cells - Cell balancing" section)
25 +
26 += v1.66.1 =
27 +
28 +[[BMS_Main_2.1_v1.66.1.srec>>FileManager.BMS_Main_2\.1_v1\.66\.1\.srec]]
29 +
30 +== Improvements ==
31 +
32 +* closing all TCP connections over Ethernet if the interface link is down
33 +
1 1  = v1.66.0 =
2 2  