... ... @@ -1,3 +1,34 @@
1 +(% class="wikigeneratedid" %)
2 +BMS Main 2.1 firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 2\.1.4\. Firmware update.WebHome]].
3 +
4 += v1.68.0 =
5 +
6 +[[BMS_Main_2.1_v1.68.0.srec>>FileManager.BMS_Main_2\.1_v1\.68\.0\.srec]]
7 +
8 +== Features ==
9 +
10 +- support for charge/discharge cycling using XD Discharger (see the sections "External equipment - Battery cycling" and "External equipment - XD Discharger (cycling)")
11 +
12 += v1.67.0 =
13 +
14 +[[BMS_Main_2.1_v1.67.0.srec>>FileManager.BMS_Main_2\.1_v1\.67\.0\.srec]]
15 +
16 +== Features ==
17 +
18 +* new additional heater controller (see the "Protections - Heater (AUX) control" section), which generates the "Heater (AUX)" signal, which can be assigned to a discrete output or relay
19 +
20 +== Improvements ==
21 +
22 +* new balancing strategy that attempts to keep the temperature of BMS Logic devices below a set value by discharging cells with higher voltages first than others (see the "Cells - Cell balancing" section)
23 +
24 += v1.66.1 =
25 +
26 +[[BMS_Main_2.1_v1.66.1.srec>>FileManager.BMS_Main_2\.1_v1\.66\.1\.srec]]
27 +
28 +== Improvements ==
29 +
30 +* closing all TCP connections over Ethernet if the interface link is down
31 +
1 1  = v1.66.0 =
2 2  
3 3  [[BMS_Main_2.1_v1.66.0.srec>>FileManager.BMS_Main_2\.1_v1\.66\.0\.srec]]