Changes for page BMS Main 2.1

Last modified by Admin on 2025/05/29 14:02

From version 13.1
edited by Admin
on 2025/05/29 14:02
Change comment: There is no comment for this version
To version 5.1
edited by Admin
on 2024/12/11 13:10
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,95 +1,6 @@
1 -(% class="box infomessage" %)
2 -(((
1 +(% class="wikigeneratedid" %)
3 3  BMS Main 2.1 firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 2\.1.4\. Firmware update.WebHome]].
4 -)))
5 5  
6 -= v1.70.2 =
7 -
8 -[[BMS_Main_2.1_v1.70.2.srec>>FileManager.BMS_Main_2\.1_v1\.70\.2\.srec]]
9 -
10 -== Improvements ==
11 -
12 -* new parameter setting a delay before measuring battery current during precharge (see the "Cells - Discharging control" section)
13 -* new counter of retry attempts showing the communication problems with BMS Logic devices (see the "Logic/Cell - Overview" section)
14 -* new flag to keep the precharging contactor closed until the precharging process is finished (in this case the "Precharge error" will not occur; see the "Cells - Discharging control" section)
15 -* new flags that force only positive and negative currents to be used to determine open circuit voltages to control the "Ready to charge" and "Ready to discharge" signals respectively
16 -
17 -== Fixes ==
18 -
19 -* resolving the issue of not being able to send log files to a remove FTP server due to a change in the file name format (v1.70.0)
20 -* increased number of retries when sending commands to BMS Logic devices, which reduces the number of false offline event detections
21 -
22 -= v1.70.1 =
23 -
24 -[[BMS_Main_2.1_v1.70.1.srec>>FileManager.BMS_Main_2\.1_v1\.70\.1\.srec]]
25 -
26 -== Improvements ==
27 -
28 -* new assignments "Low SOC" and "High charging current" for relays
29 -
30 -== Fixes ==
31 -
32 -* resolving the issue of ill-considered reduction of the battery SOC level when the cell voltage is close to the level corresponding to SOC=0% (due to the flow of a large discharge current leading to the high voltage drop on the cells)
33 -
34 -= v1.70.0 =
35 -
36 -[[BMS_Main_2.1_v1.70.0.srec>>FileManager.BMS_Main_2\.1_v1\.70\.0\.srec]]
37 -
38 -== Features ==
39 -
40 -* new parameters allowing to set different delays for battery discharge mode to detect the overcurrent error (see the "Protections - Overcurrent protection" section)
41 -* new flag that sets whether the BMS should wait for confirmation messages from the Combilift truck to start charging or not (see the "External equipment - Combilift truck" section)
42 -
43 -== Fixes ==
44 -
45 -* optimization of the logging process, minimizing the time to open the next log file if the current one is full
46 -
47 -= v1.69.1 =
48 -
49 -[[BMS_Main_2.1_v1.69.1.srec>>FileManager.BMS_Main_2\.1_v1\.69\.1\.srec]]
50 -
51 -== Fixes ==
52 -
53 -* check the HYG and Combilift confirmation flags only if the truck offline error is not set
54 -* small internal fixes
55 -
56 -= v1.69.0 =
57 -
58 -[[BMS_Main_2.1_v1.69.0.srec>>FileManager.BMS_Main_2\.1_v1\.69\.0\.srec]]
59 -
60 -== Features ==
61 -
62 -* new parameter for setting the condition for starting balancing: automatically (regardless of the command) or on the balancing request (see the "Cells - Cell balancing" section)
63 -* new option to start balancing if the cell voltage exceeds the "Voltage for forced balancing" value (see the "Cells - Cell balancing" section)
64 -* new assignment "Balancing request" for the discrete inputs (see the "Signals - Input signals" section)
65 -* new Max-Min algorithm for calculating the final battery SOC in the "Cells - SOC estimation" section
66 -* new algorithms "Automatic" and "On command" for the main contactor (see the "Cells - Main contactor" section)
67 -* new assignment "Close Main contactor" for the discrete inputs to close the main contactor by a command
68 -* new assignment "Close External 1" for the discrete inputs (see the "Signals - Input signals" section)
69 -* new assignment "External 1" for the discrete outputs and relays (see the "Signals - Output signals" section). The "External 1" output is directly controlled by the "Close External 1" command.
70 -* new "Precharge error" flag that is set when precharging cannot be completed
71 -* new flags in the "Protections - Undervoltage protection" and "Protections - Overvoltage protection" sections which allow using the calculated open circuit cell voltage instead of the actual voltage to detect the "Undervoltage" and "Overvoltage" errors, respectively
72 -* ability to check the "Ready to charge" and "Ready to discharge" signals to control the charging and discharging contactors (see the "Cells - Charging control" and "Cells - Discharging control" sections)
73 -
74 -== Improvements ==
75 -
76 -* ignoring the "Need acknowledge" flag when generating Modbus input register 0x2128 ("Error")
77 -* explicit flags to enable the use of the charging current limit for fast and/or normal charging when using the CCS Fast charge controller (see the "External equipment - CCS Fast charge controller" section)
78 -* improving resistance calculation
79 -
80 -== Fixes ==
81 -
82 -* resolving the issue where the "Need acknowledge" signal is not set if any of the device errors are not acknowledged in the error journal
83 -* using the calculated open circuit voltage to set/clear the "Ready to charge" and "Ready to discharge" signals
84 -
85 -= v1.68.0 =
86 -
87 -[[BMS_Main_2.1_v1.68.0.srec>>FileManager.BMS_Main_2\.1_v1\.68\.0\.srec]]
88 -
89 -== Features ==
90 -
91 -- support for charge/discharge cycling using XD Discharger (see the sections "External equipment - Battery cycling" and "External equipment - XD Discharger (cycling)")
92 -
93 93  = v1.67.0 =
94 94  
95 95  [[BMS_Main_2.1_v1.67.0.srec>>FileManager.BMS_Main_2\.1_v1\.67\.0\.srec]]