Changes for page BMS Main 2.1
Last modified by Admin on 2026/01/30 09:17
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -3,6 +3,53 @@ 3 3 BMS Main 2.1 firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 2\.1.4\. Firmware update.WebHome]]. 4 4 ))) 5 5 6 += v1.70.6 = 7 + 8 +[[BMS_Main_2.1_v1.70.6.srec>>FileManager.BMS_Main_2\.1_v1\.70\.6\.srec]] 9 + 10 +== Improvements == 11 + 12 +* support for 32-bit BMS Logic serial numbers 13 +* increasing the stability of the BMS Wi-Fi v2 driver 14 + 15 +== Fixes == 16 + 17 +* resolving the problem of charge, discharge, and charge/discharge contactors closing when the "Precharge request" signal is set 18 +* synchronization of the precharge procedure with the charge/discharge algorithms, so that precharge is stopped if charging and discharging are prohibited 19 +* resolving the stability problem when the SD card is full 20 +* small fixes in current maps 21 + 22 += v1.70.5 = 23 + 24 +[[BMS_Main_2.1_v1.70.5.srec>>FileManager.BMS_Main_2\.1_v1\.70\.5\.srec]] 25 + 26 +== Fixes == 27 + 28 +* resolving the issue of Ethernet packet retransmission 29 + 30 += v1.70.4 = 31 + 32 +[[BMS_Main_2.1_v1.70.4.srec>>FileManager.BMS_Main_2\.1_v1\.70\.4\.srec]] 33 + 34 +== Improvements == 35 + 36 +* new flags for generating the "Ready to charge" and "Ready to discharge" signals using the actual cell voltage instead of the calculated open circuit voltage (see the "Cells - Charging control" and "Cells - Discharging control" sections) 37 + 38 +== Fixes == 39 + 40 +* resolving the issue of rebooting the device if formatting the SD card is activated 41 + 42 += v1.70.3 = 43 + 44 +[[BMS_Main_2.1_v1.70.3.srec>>FileManager.BMS_Main_2\.1_v1\.70\.3\.srec]] 45 + 46 +== Improvements == 47 + 48 +* new flags that force the precharge process to finish if the battery current is negative (in case the battery will be charging) or positive (in case the battery will be discharging); see the "Cells - Charging control" and "Cells - Discharging control" sections 49 +* 30 second delay when remounting SD card after detecting mount error 50 +* new flag to prevent the "HYG offline" error from occurring if the "Charger connected" signal is set (see the "External equipment - HYG Class I-III truck" section) 51 +* new flag that controls whether to wait for confirmation from the HYG truck or not, to allow the battery to be charged (see the "External equipment - HYG Class I-III truck" section) 52 + 6 6 = v1.70.2 = 7 7 8 8 [[BMS_Main_2.1_v1.70.2.srec>>FileManager.BMS_Main_2\.1_v1\.70\.2\.srec]]