Changes for page BMS Main 2.1

Last modified by Admin on 2026/01/30 09:17

From version 13.1
edited by Admin
on 2025/05/29 14:02
Change comment: There is no comment for this version
To version 17.1
edited by Admin
on 2026/01/30 09:17
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -3,6 +3,53 @@
3 3  BMS Main 2.1 firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 2\.1.4\. Firmware update.WebHome]].
4 4  )))
5 5  
6 += v1.70.6 =
7 +
8 +[[BMS_Main_2.1_v1.70.6.srec>>FileManager.BMS_Main_2\.1_v1\.70\.6\.srec]]
9 +
10 +== Improvements ==
11 +
12 +* support for 32-bit BMS Logic serial numbers
13 +* increasing the stability of the BMS Wi-Fi v2 driver
14 +
15 +== Fixes ==
16 +
17 +* resolving the problem of charge, discharge, and charge/discharge contactors closing when the "Precharge request" signal is set
18 +* synchronization of the precharge procedure with the charge/discharge algorithms, so that precharge is stopped if charging and discharging are prohibited
19 +* resolving the stability problem when the SD card is full
20 +* small fixes in current maps
21 +
22 += v1.70.5 =
23 +
24 +[[BMS_Main_2.1_v1.70.5.srec>>FileManager.BMS_Main_2\.1_v1\.70\.5\.srec]]
25 +
26 +== Fixes ==
27 +
28 +* resolving the issue of Ethernet packet retransmission
29 +
30 += v1.70.4 =
31 +
32 +[[BMS_Main_2.1_v1.70.4.srec>>FileManager.BMS_Main_2\.1_v1\.70\.4\.srec]]
33 +
34 +== Improvements ==
35 +
36 +* new flags for generating the "Ready to charge" and "Ready to discharge" signals using the actual cell voltage instead of the calculated open circuit voltage (see the "Cells - Charging control" and "Cells - Discharging control" sections)
37 +
38 +== Fixes ==
39 +
40 +* resolving the issue of rebooting the device if formatting the SD card is activated
41 +
42 += v1.70.3 =
43 +
44 +[[BMS_Main_2.1_v1.70.3.srec>>FileManager.BMS_Main_2\.1_v1\.70\.3\.srec]]
45 +
46 +== Improvements ==
47 +
48 +* new flags that force the precharge process to finish if the battery current is negative (in case the battery will be charging) or positive (in case the battery will be discharging); see the "Cells - Charging control" and "Cells - Discharging control" sections
49 +* 30 second delay when remounting SD card after detecting mount error
50 +* new flag to prevent the "HYG offline" error from occurring if the "Charger connected" signal is set (see the "External equipment - HYG Class I-III truck" section)
51 +* new flag that controls whether to wait for confirmation from the HYG truck or not, to allow the battery to be charged (see the "External equipment - HYG Class I-III truck" section)
52 +
6 6  = v1.70.2 =
7 7  
8 8  [[BMS_Main_2.1_v1.70.2.srec>>FileManager.BMS_Main_2\.1_v1\.70\.2\.srec]]