Changes for page BMS Main 2.1
Last modified by Admin on 2025/06/24 07:30
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -3,6 +3,17 @@ 3 3 BMS Main 2.1 firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 2\.1.4\. Firmware update.WebHome]]. 4 4 ))) 5 5 6 += v1.70.3 = 7 + 8 +[[BMS_Main_2.1_v1.70.3.srec>>FileManager.BMS_Main_2\.1_v1\.70\.3\.srec]] 9 + 10 +== Improvements == 11 + 12 +* new flags that force the precharge process to finish if the battery current is negative (in case the battery will be charging) or positive (in case the battery will be discharging); see the "Cells - Charging control" and "Cells - Discharging control" sections 13 +* 30 second delay when remounting SD card after detecting mount error 14 +* new flag to prevent the "HYG offline" error from occurring if the "Charger connected" signal is set (see the "External equipment - HYG Class I-III truck" section) 15 +* new flag that controls whether to wait for confirmation from the HYG truck or not, to allow the battery to be charged (see the "External equipment - HYG Class I-III truck" section) 16 + 6 6 = v1.70.2 = 7 7 8 8 [[BMS_Main_2.1_v1.70.2.srec>>FileManager.BMS_Main_2\.1_v1\.70\.2\.srec]]