Changes for page BMS Main 2.1
Last modified by Admin on 2025/04/14 10:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -3,31 +3,6 @@ 3 3 BMS Main 2.1 firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 2\.1.4\. Firmware update.WebHome]]. 4 4 ))) 5 5 6 -= v1.70.1 = 7 - 8 -[[BMS_Main_2.1_v1.70.1.srec>>FileManager.BMS_Main_2\.1_v1\.70\.1\.srec]] 9 - 10 -== Improvements == 11 - 12 -* new assignments "Low SOC" and "High charging current" for relays 13 - 14 -== Fixes == 15 - 16 -* resolving the issue of ill-considered reduction of the battery SOC level when the cell voltage is close to the level corresponding to SOC=0% (due to the flow of a large discharge current leading to the high voltage drop on the cells) 17 - 18 -= v1.70.0 = 19 - 20 -[[BMS_Main_2.1_v1.70.0.srec>>FileManager.BMS_Main_2\.1_v1\.70\.0\.srec]] 21 - 22 -== Features == 23 - 24 -* new parameters allowing to set different delays for battery discharge mode to detect the overcurrent error (see the "Protections - Overcurrent protection" section) 25 -* new flag that sets whether the BMS should wait for confirmation messages from the Combilift truck to start charging or not (see the "External equipment - Combilift truck" section) 26 - 27 -== Fixes == 28 - 29 -* optimization of the logging process, minimizing the time to open the next log file if the current one is full 30 - 31 31 = v1.69.1 = 32 32 33 33 [[BMS_Main_2.1_v1.69.1.srec>>FileManager.BMS_Main_2\.1_v1\.69\.1\.srec]]