3 3  BMS Main 2.1 firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 2\.1.4\. Firmware update.WebHome]].
4 4  )))
5 5  
6 += v1.70.2 =
7 +
8 +[[BMS_Main_2.1_v1.70.2.srec>>FileManager.BMS_Main_2\.1_v1\.70\.2\.srec]]
9 +
10 +== Improvements ==
11 +
12 +* new parameter setting a delay before measuring battery current during precharge (see the "Cells - Discharging control" section)
13 +* new counter of retry attempts showing the communication problems with BMS Logic devices (see the "Logic/Cell - Overview" section)
14 +* new flag to keep the precharging contactor closed until the precharging process is finished (in this case the "Precharge error" will not occur; see the "Cells - Discharging control" section)
15 +* new flags that force only positive and negative currents to be used to determine open circuit voltages to control the "Ready to charge" and "Ready to discharge" signals respectively
16 +
17 +== Fixes ==
18 +
19 +* resolving the issue of not being able to send log files to a remove FTP server due to a change in the file name format (v1.70.0)
20 +* increased number of retries when sending commands to BMS Logic devices, which reduces the number of false offline event detections
21 +