Changes for page BMS Main 2.1
Last modified by Admin on 2025/05/29 14:02
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -3,6 +3,22 @@ 3 3 BMS Main 2.1 firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 2\.1.4\. Firmware update.WebHome]]. 4 4 ))) 5 5 6 += v1.70.2 = 7 + 8 +[[BMS_Main_2.1_v1.70.2.srec>>FileManager.BMS_Main_2\.1_v1\.70\.2\.srec]] 9 + 10 +== Improvements == 11 + 12 +* new parameter setting a delay before measuring battery current during precharge (see the "Cells - Discharging control" section) 13 +* new counter of retry attempts showing the communication problems with BMS Logic devices (see the "Logic/Cell - Overview" section) 14 +* new flag to keep the precharging contactor closed until the precharging process is finished (in this case the "Precharge error" will not occur; see the "Cells - Discharging control" section) 15 +* new flags that force only positive and negative currents to be used to determine open circuit voltages to control the "Ready to charge" and "Ready to discharge" signals respectively 16 + 17 +== Fixes == 18 + 19 +* resolving the issue of not being able to send log files to a remove FTP server due to a change in the file name format (v1.70.0) 20 +* increased number of retries when sending commands to BMS Logic devices, which reduces the number of false offline event detections 21 + 6 6 = v1.70.1 = 7 7 8 8 [[BMS_Main_2.1_v1.70.1.srec>>FileManager.BMS_Main_2\.1_v1\.70\.1\.srec]]