Changes for page BMS Main 2.1

Last modified by Admin on 2025/04/14 10:35

From version 11.1
edited by Admin
on 2025/04/02 10:05
Change comment: There is no comment for this version
To version 2.1
edited by Admin
on 2024/11/22 09:06
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,87 +85,3 @@
1 -(% class="box infomessage" %)
2 -(((
3 -BMS Main 2.1 firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 2\.1.4\. Firmware update.WebHome]].
4 -)))
5 -
6 -= v1.70.0 =
7 -
8 -[[BMS_Main_2.1_v1.70.0.srec>>FileManager.BMS_Main_2\.1_v1\.70\.0\.srec]]
9 -
10 -== Features ==
11 -
12 -* new parameters allowing to set different delays for battery discharge mode to detect the overcurrent error (see the "Protections - Overcurrent protection" section)
13 -* new flag that sets whether the BMS should wait for confirmation messages from the Combilift truck to start charging or not (see the "External equipment - Combilift truck" section)
14 -
15 -== Fixes ==
16 -
17 -* optimization of the logging process, minimizing the time to open the next log file if the current one is full
18 -
19 -= v1.69.1 =
20 -
21 -[[BMS_Main_2.1_v1.69.1.srec>>FileManager.BMS_Main_2\.1_v1\.69\.1\.srec]]
22 -
23 -== Fixes ==
24 -
25 -* check the HYG and Combilift confirmation flags only if the truck offline error is not set
26 -* small internal fixes
27 -
28 -= v1.69.0 =
29 -
30 -[[BMS_Main_2.1_v1.69.0.srec>>FileManager.BMS_Main_2\.1_v1\.69\.0\.srec]]
31 -
32 -== Features ==
33 -
34 -* new parameter for setting the condition for starting balancing: automatically (regardless of the command) or on the balancing request (see the "Cells - Cell balancing" section)
35 -* new option to start balancing if the cell voltage exceeds the "Voltage for forced balancing" value (see the "Cells - Cell balancing" section)
36 -* new assignment "Balancing request" for the discrete inputs (see the "Signals - Input signals" section)
37 -* new Max-Min algorithm for calculating the final battery SOC in the "Cells - SOC estimation" section
38 -* new algorithms "Automatic" and "On command" for the main contactor (see the "Cells - Main contactor" section)
39 -* new assignment "Close Main contactor" for the discrete inputs to close the main contactor by a command
40 -* new assignment "Close External 1" for the discrete inputs (see the "Signals - Input signals" section)
41 -* new assignment "External 1" for the discrete outputs and relays (see the "Signals - Output signals" section). The "External 1" output is directly controlled by the "Close External 1" command.
42 -* new "Precharge error" flag that is set when precharging cannot be completed
43 -* new flags in the "Protections - Undervoltage protection" and "Protections - Overvoltage protection" sections which allow using the calculated open circuit cell voltage instead of the actual voltage to detect the "Undervoltage" and "Overvoltage" errors, respectively
44 -* ability to check the "Ready to charge" and "Ready to discharge" signals to control the charging and discharging contactors (see the "Cells - Charging control" and "Cells - Discharging control" sections)
45 -
46 -== Improvements ==
47 -
48 -* ignoring the "Need acknowledge" flag when generating Modbus input register 0x2128 ("Error")
49 -* explicit flags to enable the use of the charging current limit for fast and/or normal charging when using the CCS Fast charge controller (see the "External equipment - CCS Fast charge controller" section)
50 -* improving resistance calculation
51 -
52 -== Fixes ==
53 -
54 -* resolving the issue where the "Need acknowledge" signal is not set if any of the device errors are not acknowledged in the error journal
55 -* using the calculated open circuit voltage to set/clear the "Ready to charge" and "Ready to discharge" signals
56 -
57 -= v1.68.0 =
58 -
59 -[[BMS_Main_2.1_v1.68.0.srec>>FileManager.BMS_Main_2\.1_v1\.68\.0\.srec]]
60 -
61 -== Features ==
62 -
63 -- support for charge/discharge cycling using XD Discharger (see the sections "External equipment - Battery cycling" and "External equipment - XD Discharger (cycling)")
64 -
65 -= v1.67.0 =
66 -
67 -[[BMS_Main_2.1_v1.67.0.srec>>FileManager.BMS_Main_2\.1_v1\.67\.0\.srec]]
68 -
69 -== Features ==
70 -
71 -* new additional heater controller (see the "Protections - Heater (AUX) control" section), which generates the "Heater (AUX)" signal, which can be assigned to a discrete output or relay
72 -
73 -== Improvements ==
74 -
75 -* new balancing strategy that attempts to keep the temperature of BMS Logic devices below a set value by discharging cells with higher voltages first than others (see the "Cells - Cell balancing" section)
76 -
77 -= v1.66.1 =
78 -
79 -[[BMS_Main_2.1_v1.66.1.srec>>FileManager.BMS_Main_2\.1_v1\.66\.1\.srec]]
80 -
81 -== Improvements ==
82 -
83 -* closing all TCP connections over Ethernet if the interface link is down
84 -
85 85  = v1.66.0 =