Changes for page BMS Main 2.1
Last modified by Admin on 2025/04/14 10:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -3,57 +3,6 @@ 3 3 BMS Main 2.1 firmware update procedure is described [[here>>doc:Battery management systems.BMS Main 2\.1.4\. Firmware update.WebHome]]. 4 4 ))) 5 5 6 -= v1.70.0 = 7 - 8 -[[BMS_Main_2.1_v1.70.0.srec>>FileManager.BMS_Main_2\.1_v1\.70\.0\.srec]] 9 - 10 -== Features == 11 - 12 -* new parameters allowing to set different delays for battery discharge mode to detect the overcurrent error (see the "Protections - Overcurrent protection" section) 13 -* new flag that sets whether the BMS should wait for confirmation messages from the Combilift truck to start charging or not (see the "External equipment - Combilift truck" section) 14 - 15 -== Fixes == 16 - 17 -* optimization of the logging process, minimizing the time to open the next log file if the current one is full 18 - 19 -= v1.69.1 = 20 - 21 -[[BMS_Main_2.1_v1.69.1.srec>>FileManager.BMS_Main_2\.1_v1\.69\.1\.srec]] 22 - 23 -== Fixes == 24 - 25 -* check the HYG and Combilift confirmation flags only if the truck offline error is not set 26 -* small internal fixes 27 - 28 -= v1.69.0 = 29 - 30 -[[BMS_Main_2.1_v1.69.0.srec>>FileManager.BMS_Main_2\.1_v1\.69\.0\.srec]] 31 - 32 -== Features == 33 - 34 -* new parameter for setting the condition for starting balancing: automatically (regardless of the command) or on the balancing request (see the "Cells - Cell balancing" section) 35 -* new option to start balancing if the cell voltage exceeds the "Voltage for forced balancing" value (see the "Cells - Cell balancing" section) 36 -* new assignment "Balancing request" for the discrete inputs (see the "Signals - Input signals" section) 37 -* new Max-Min algorithm for calculating the final battery SOC in the "Cells - SOC estimation" section 38 -* new algorithms "Automatic" and "On command" for the main contactor (see the "Cells - Main contactor" section) 39 -* new assignment "Close Main contactor" for the discrete inputs to close the main contactor by a command 40 -* new assignment "Close External 1" for the discrete inputs (see the "Signals - Input signals" section) 41 -* new assignment "External 1" for the discrete outputs and relays (see the "Signals - Output signals" section). The "External 1" output is directly controlled by the "Close External 1" command. 42 -* new "Precharge error" flag that is set when precharging cannot be completed 43 -* new flags in the "Protections - Undervoltage protection" and "Protections - Overvoltage protection" sections which allow using the calculated open circuit cell voltage instead of the actual voltage to detect the "Undervoltage" and "Overvoltage" errors, respectively 44 -* ability to check the "Ready to charge" and "Ready to discharge" signals to control the charging and discharging contactors (see the "Cells - Charging control" and "Cells - Discharging control" sections) 45 - 46 -== Improvements == 47 - 48 -* ignoring the "Need acknowledge" flag when generating Modbus input register 0x2128 ("Error") 49 -* explicit flags to enable the use of the charging current limit for fast and/or normal charging when using the CCS Fast charge controller (see the "External equipment - CCS Fast charge controller" section) 50 -* improving resistance calculation 51 - 52 -== Fixes == 53 - 54 -* resolving the issue where the "Need acknowledge" signal is not set if any of the device errors are not acknowledged in the error journal 55 -* using the calculated open circuit voltage to set/clear the "Ready to charge" and "Ready to discharge" signals 56 - 57 57 = v1.68.0 = 58 58 59 59 [[BMS_Main_2.1_v1.68.0.srec>>FileManager.BMS_Main_2\.1_v1\.68\.0\.srec]]