Changes for page BMS Main 2.1
Last modified by Admin on 2025/04/14 10:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,0 +1,31 @@ 1 += v1.67.0 = 2 + 3 +[[BMS_Main_2.1_v1.67.0.srec>>FileManager.BMS_Main_2\.1_v1\.67\.0\.srec]] 4 + 5 +== Features == 6 + 7 +* new additional heater controller (see the "Protections - Heater (AUX) control" section), which generates the "Heater (AUX)" signal, which can be assigned to a discrete output or relay 8 + 9 +== Improvements == 10 + 11 +* new balancing strategy that attempts to keep the temperature of BMS Logic devices below a set value by discharging cells with higher voltages first than others (see the "Cells - Cell balancing" section) 12 + 13 += v1.66.1 = 14 + 15 +[[BMS_Main_2.1_v1.66.1.srec>>FileManager.BMS_Main_2\.1_v1\.66\.1\.srec]] 16 + 17 +== Improvements == 18 + 19 +* closing all TCP connections over Ethernet if the interface link is down 20 + 21 += v1.66.0 = 22 + 23 +[[BMS_Main_2.1_v1.66.0.srec>>FileManager.BMS_Main_2\.1_v1\.66\.0\.srec]] 24 + 25 +== Features == 26 + 27 +* support for the insulation monitoring device BMS IMD (see the section "External equipment - BMS IMD device") 28 + 29 +== Improvements == 30 + 31 +* new parameters for switching off the Discharging (AUX) relay when the cell voltage is too low (see the "Cells - Discharging (AUX) control" section)