BMS Main 2.1
Last modified by Admin on 2025/02/19 10:47
v1.69.1
Fixes
- check the HYG and Combilift confirmation flags only if the truck offline error is not set
- small internal fixes
v1.69.0
Features
- new parameter for setting the condition for starting balancing: automatically (regardless of the command) or on the balancing request (see the "Cells - Cell balancing" section)
- new option to start balancing if the cell voltage exceeds the "Voltage for forced balancing" value (see the "Cells - Cell balancing" section)
- new assignment "Balancing request" for the discrete inputs (see the "Signals - Input signals" section)
- new Max-Min algorithm for calculating the final battery SOC in the "Cells - SOC estimation" section
- new algorithms "Automatic" and "On command" for the main contactor (see the "Cells - Main contactor" section)
- new assignment "Close Main contactor" for the discrete inputs to close the main contactor by a command
- new assignment "Close External 1" for the discrete inputs (see the "Signals - Input signals" section)
- new assignment "External 1" for the discrete outputs and relays (see the "Signals - Output signals" section). The "External 1" output is directly controlled by the "Close External 1" command.
- new "Precharge error" flag that is set when precharging cannot be completed
- new flags in the "Protections - Undervoltage protection" and "Protections - Overvoltage protection" sections which allow using the calculated open circuit cell voltage instead of the actual voltage to detect the "Undervoltage" and "Overvoltage" errors, respectively
- ability to check the "Ready to charge" and "Ready to discharge" signals to control the charging and discharging contactors (see the "Cells - Charging control" and "Cells - Discharging control" sections)
Improvements
- ignoring the "Need acknowledge" flag when generating Modbus input register 0x2128 ("Error")
- explicit flags to enable the use of the charging current limit for fast and/or normal charging when using the CCS Fast charge controller (see the "External equipment - CCS Fast charge controller" section)
- improving resistance calculation
Fixes
- resolving the issue where the "Need acknowledge" signal is not set if any of the device errors are not acknowledged in the error journal
- using the calculated open circuit voltage to set/clear the "Ready to charge" and "Ready to discharge" signals
v1.68.0
Features
- support for charge/discharge cycling using XD Discharger (see the sections "External equipment - Battery cycling" and "External equipment - XD Discharger (cycling)")
v1.67.0
Features
- new additional heater controller (see the "Protections - Heater (AUX) control" section), which generates the "Heater (AUX)" signal, which can be assigned to a discrete output or relay
Improvements
- new balancing strategy that attempts to keep the temperature of BMS Logic devices below a set value by discharging cells with higher voltages first than others (see the "Cells - Cell balancing" section)
v1.66.1
Improvements
- closing all TCP connections over Ethernet if the interface link is down
v1.66.0
Features
- support for the insulation monitoring device BMS IMD (see the section "External equipment - BMS IMD device")
Improvements
- new parameters for switching off the Discharging (AUX) relay when the cell voltage is too low (see the "Cells - Discharging (AUX) control" section)