Wiki source code of BMS Repeater

Last modified by Admin on 2025/02/20 13:20

Hide last authors
Admin 2.1 1 = General information =
Admin 1.1 2
3
4 [[image:1734105245109-437.png||data-xwiki-image-style-alignment="center" height="137" width="300"]]
5
Admin 2.1 6 The BMS Repeater is a device for relaying RS-485 signals from one subnetwork to another and vice versa.
Admin 1.1 7
8 The device provides galvanic isolation up to 3500 V RMS.
9
10 = Specifications =
11
12 |**Parameter**|**Value**
13 |Supply voltage, V|5.0±0.5
14 |Current consumption @5 V, mA (no load; max)|40
15 |RS-485 baud rate, bps (max)|115200
16 |Output voltage, V|5.0±0.5
17 |Output current, mA (max)|400
18 |Dimensions (length × width × height), mm|64 × 30 × 16
19 |Weight, g|13±2
20 |(% colspan="2" %)**Operating conditions**
21 |Operating temperature range, ° С|-40÷75
22 |Degree of protection from external influences|IP00
Admin 3.1 23 |Header types|Molex series Mini-Fit
Admin 1.1 24
25 = Connection =
26
Admin 2.1 27 The BMS Repeater a header to connect the any BMS Main board and a header to connect any BMS Logic board. It also has jumpers to connect bias resistors to the RS-485 bus subnetworks.
Admin 1.1 28
29 [[image:1734105319233-615.png||data-xwiki-image-style-alignment="center" height="353" width="350"]]
30
31 |**Parameter**|**Value**
32 |Overall dimensions (length × width × height), mm|64 × 30 × 16
33 |Mounting dimensions (length × width), mm|57 × 23
34 |Mounting holes|M3
35
Admin 2.1 36 == X1 – header for communication with BMS Main board ==
Admin 1.1 37
Admin 3.1 38 Receptacle Housing: Molex 39012040. Terminals: Molex 5556
39
Admin 1.1 40 [[image:1734105400608-295.png||data-xwiki-image-style-alignment="center" height="83" width="75"]]
41
42 |**Pin**|**Name**|**Description**
43 |**1**|**RS485_A1**|RS-485 line A for communication with the BMS Main
44 |**2**|**RS485_B1**|RS-485 line B for communication with the BMS Main
45 |**3**|**+5V**|Supply voltage 5V
46 |**4**|**GND1**|Ground
47
Admin 2.1 48 == X2 – header for communication with BMS Logic board ==
Admin 1.1 49
Admin 3.1 50 Receptacle Housing: Molex 39012040. Terminals: Molex 5556
51
Admin 1.1 52 [[image:1734105400608-295.png||data-xwiki-image-style-alignment="center" height="83" width="75"]]
53
54 |**Pin**|**Name**|**Description**
55 |**1**|**RS485_A2**|RS-485 line A for communication with BMS Logic
56 |**2**|**RS485_B2**|RS-485 line B for communication with BMS Logic
57 |**3**|**OUT_5V**|Output voltage 5V, max 400 mA
58 |**4**|**GND2**|Ground
59
60 == P1, P2 – jumpers for bias resistors of subnetwork 1 ==
61
62 To connect the bias resistors setting proper RS-485 bus levels on the BMS Main subnetwork install the P1 and P2 jumpers.
63
64 (% class="box warningmessage" %)
65 (((
66 Do not connect the second pair of bias resistors to the same RS-485 subnetwork.
67 )))
68
69 == P3, P4 – jumpers for bias resistors of subnetwork 2 ==
70
71 To connect the bias resistors setting proper RS-485 bus levels on the BMS Logic subnetwork install the P3 and P4 jumpers.
72
73 (% class="box warningmessage" %)