BMS Repeater

Version 2.1 by Admin on 2024/12/23 17:08

General information

1734105245109-437.png

The BMS Repeater is a device for relaying RS-485 signals from one subnetwork to another and vice versa.

The device provides galvanic isolation up to 3500 V RMS.

Specifications

ParameterValue
Supply voltage, V5.0±0.5
Current consumption @5 V, mA (no load; max)40
RS-485 baud rate, bps (max)115200
Output voltage, V5.0±0.5
Output current, mA (max)400
Dimensions (length × width × height), mm64 × 30 × 16
Weight, g13±2
Operating conditions
Operating temperature range, ° С-40÷75
Degree of protection from external influencesIP00

Connection

The BMS Repeater a header to connect the any BMS Main board and a header to connect any BMS Logic board. It also has jumpers to connect bias resistors to the RS-485 bus subnetworks.

1734105319233-615.png

ParameterValue
Overall dimensions (length × width × height), mm64 × 30 × 16
Mounting dimensions (length × width), mm57 × 23
Mounting holesM3
Header typesMolex series Mini-Fit

X1 – header for communication with BMS Main board

1734105400608-295.png

PinNameDescription
1RS485_A1RS-485 line A for communication with the BMS Main
2RS485_B1RS-485 line B for communication with the BMS Main
3+5VSupply voltage 5V
4GND1Ground

X2 – header for communication with BMS Logic board

1734105400608-295.png

PinNameDescription
1RS485_A2RS-485 line A for communication with BMS Logic
2RS485_B2RS-485 line B for communication with BMS Logic
3OUT_5VOutput voltage 5V, max 400 mA
4GND2Ground

P1, P2 – jumpers for bias resistors of subnetwork 1

To connect the bias resistors setting proper RS-485 bus levels on the BMS Main subnetwork install the P1 and P2 jumpers.

Do not connect the second pair of bias resistors to the same RS-485 subnetwork.

P3, P4 – jumpers for bias resistors of subnetwork 2

To connect the bias resistors setting proper RS-485 bus levels on the BMS Logic subnetwork install the P3 and P4 jumpers.

Do not connect the second pair of bias resistors to the same RS-485 subnetwork.