1 = General information =
2
3
4 [[image:1734105245109-437.png||data-xwiki-image-style-alignment="center" height="137" width="300"]]
5
6 The BMS Repeater is a device for relaying RS-485 signals from one subnetwork to another and vice versa.
7
8 The device provides galvanic isolation up to 3500 V RMS.
9
10 = Specifications =
11
12 |**Parameter**|**Value**
13 |Supply voltage, V|5.0±0.5
14 |Current consumption @5 V, mA (no load; max)|40
15 |RS-485 baud rate, bps (max)|115200
16 |Output voltage, V|5.0±0.5
17 |Output current, mA (max)|400
18 |Dimensions (length × width × height), mm|64 × 30 × 16
19 |Weight, g|13±2
20 |(% colspan="2" %)**Operating conditions**
21 |Operating temperature range, ° С|-40÷75
22 |Degree of protection from external influences|IP00
23
24 = Connection =
25
26 The BMS Repeater a header to connect the any BMS Main board and a header to connect any BMS Logic board. It also has jumpers to connect bias resistors to the RS-485 bus subnetworks.
27
28 [[image:1734105319233-615.png||data-xwiki-image-style-alignment="center" height="353" width="350"]]
29
30 |**Parameter**|**Value**
31 |Overall dimensions (length × width × height), mm|64 × 30 × 16
32 |Mounting dimensions (length × width), mm|57 × 23
33 |Mounting holes|M3
34 |Header types|Molex series Mini-Fit
35
36 == X1 – header for communication with BMS Main board ==
37
38 [[image:1734105400608-295.png||data-xwiki-image-style-alignment="center" height="83" width="75"]]
39
40 |**Pin**|**Name**|**Description**
41 |**1**|**RS485_A1**|RS-485 line A for communication with the BMS Main
42 |**2**|**RS485_B1**|RS-485 line B for communication with the BMS Main
43 |**3**|**+5V**|Supply voltage 5V
44 |**4**|**GND1**|Ground
45
46 == X2 – header for communication with BMS Logic board ==
47
48 [[image:1734105400608-295.png||data-xwiki-image-style-alignment="center" height="83" width="75"]]
49
50 |**Pin**|**Name**|**Description**
51 |**1**|**RS485_A2**|RS-485 line A for communication with BMS Logic
52 |**2**|**RS485_B2**|RS-485 line B for communication with BMS Logic
53 |**3**|**OUT_5V**|Output voltage 5V, max 400 mA
54 |**4**|**GND2**|Ground
55
56 == P1, P2 – jumpers for bias resistors of subnetwork 1 ==
57
58 To connect the bias resistors setting proper RS-485 bus levels on the BMS Main subnetwork install the P1 and P2 jumpers.
59
60 (% class="box warningmessage" %)
61 (((
62 Do not connect the second pair of bias resistors to the same RS-485 subnetwork.
63 )))
64
65 == P3, P4 – jumpers for bias resistors of subnetwork 2 ==
66
67 To connect the bias resistors setting proper RS-485 bus levels on the BMS Logic subnetwork install the P3 and P4 jumpers.
68
69 (% class="box warningmessage" %)
70 (((
71 Do not connect the second pair of bias resistors to the same RS-485 subnetwork.
72 )))