Wiki source code of BMS Repeater
Show last authors
author | version | line-number | content |
---|---|---|---|
1 | = General information = | ||
2 | |||
3 | |||
4 | [[image:1734105245109-437.png||data-xwiki-image-style-alignment="center" height="137" width="300"]] | ||
5 | |||
6 | The BMS Repeater 1.x is a device for relaying RS-485 signals from one subnetwork to another and vice versa. | ||
7 | |||
8 | The device provides galvanic isolation up to 3500 V RMS. | ||
9 | |||
10 | = Specifications = | ||
11 | |||
12 | |**Parameter**|**Value** | ||
13 | |Supply voltage, V|5.0±0.5 | ||
14 | |Current consumption @5 V, mA (no load; max)|40 | ||
15 | |RS-485 baud rate, bps (max)|115200 | ||
16 | |Output voltage, V|5.0±0.5 | ||
17 | |Output current, mA (max)|400 | ||
18 | |Dimensions (length × width × height), mm|64 × 30 × 16 | ||
19 | |Weight, g|13±2 | ||
20 | |(% colspan="2" %)**Operating conditions** | ||
21 | |Operating temperature range, ° С|-40÷75 | ||
22 | |Degree of protection from external influences|IP00 | ||
23 | |||
24 | = Connection = | ||
25 | |||
26 | The BMS Repeater 1.x has a header to connect the BMS Main (X1) and a header to connect BMS Logic (X2). It also has jumpers to connect bias resistors to the RS-485 bus subnetworks. | ||
27 | |||
28 | [[image:1734105319233-615.png||data-xwiki-image-style-alignment="center" height="353" width="350"]] | ||
29 | |||
30 | |**Parameter**|**Value** | ||
31 | |Overall dimensions (length × width × height), mm|64 × 30 × 16 | ||
32 | |Mounting dimensions (length × width), mm|57 × 23 | ||
33 | |Mounting holes|M3 | ||
34 | |Header types|Molex series Mini-Fit | ||
35 | |||
36 | == X1 – header for communication with BMS Main == | ||
37 | |||
38 | [[image:1734105400608-295.png||data-xwiki-image-style-alignment="center" height="83" width="75"]] | ||
39 | |||
40 | |**Pin**|**Name**|**Description** | ||
41 | |**1**|**RS485_A1**|RS-485 line A for communication with the BMS Main | ||
42 | |**2**|**RS485_B1**|RS-485 line B for communication with the BMS Main | ||
43 | |**3**|**+5V**|Supply voltage 5V | ||
44 | |**4**|**GND1**|Ground | ||
45 | |||
46 | == X2 – header for communication with BMS Logic == | ||
47 | |||
48 | [[image:1734105400608-295.png||data-xwiki-image-style-alignment="center" height="83" width="75"]] | ||
49 | |||
50 | |**Pin**|**Name**|**Description** | ||
51 | |**1**|**RS485_A2**|RS-485 line A for communication with BMS Logic | ||
52 | |**2**|**RS485_B2**|RS-485 line B for communication with BMS Logic | ||
53 | |**3**|**OUT_5V**|Output voltage 5V, max 400 mA | ||
54 | |**4**|**GND2**|Ground | ||
55 | |||
56 | == P1, P2 – jumpers for bias resistors of subnetwork 1 == | ||
57 | |||
58 | To connect the bias resistors setting proper RS-485 bus levels on the BMS Main subnetwork install the P1 and P2 jumpers. | ||
59 | |||
60 | (% class="box warningmessage" %) | ||
61 | ((( | ||
62 | Do not connect the second pair of bias resistors to the same RS-485 subnetwork. | ||
63 | ))) | ||
64 | |||
65 | == P3, P4 – jumpers for bias resistors of subnetwork 2 == | ||
66 | |||
67 | To connect the bias resistors setting proper RS-485 bus levels on the BMS Logic subnetwork install the P3 and P4 jumpers. | ||
68 | |||
69 | (% class="box warningmessage" %) | ||
70 | ((( | ||
71 | Do not connect the second pair of bias resistors to the same RS-485 subnetwork. | ||
72 | ))) |