Changes for page BMS Repeater

Last modified by Admin on 2025/03/18 13:18

From version 5.1
edited by Admin
on 2025/03/18 13:18
Change comment: There is no comment for this version
To version 1.2
edited by Admin
on 2024/12/13 16:00
Change comment: Update document after refactoring.

Summary

Details

Page properties
Content
... ... @@ -1,9 +1,9 @@
1 -= General information =
1 += General information =
2 2  
3 3  
4 4  [[image:1734105245109-437.png||data-xwiki-image-style-alignment="center" height="137" width="300"]]
5 5  
6 -The BMS Repeater is a device for relaying RS-485 signals from one subnetwork to another and vice versa.
6 +The BMS Repeater 1.x is a device for relaying RS-485 signals from one subnetwork to another and vice versa.
7 7  
8 8  The device provides galvanic isolation up to 3500 V RMS.
9 9  
... ... @@ -20,17 +20,11 @@
20 20  |(% colspan="2" %)**Operating conditions**
21 21  |Operating temperature range, ° С|-40÷75
22 22  |Degree of protection from external influences|IP00
23 -|Header types|Molex series Mini-Fit
24 24  
25 25  = Connection =
26 26  
27 -(% class="box errormessage" %)
28 -(((
29 -The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools and appliances. To prevent the damage of device avoid electrostatic discharges while working with the battery.
30 -)))
26 +The BMS Repeater 1.x has a header to connect the BMS Main (X1) and a header to connect BMS Logic (X2). It also has jumpers to connect bias resistors to the RS-485 bus subnetworks.
31 31  
32 -The BMS Repeater a header to connect the any BMS Main board and a header to connect any BMS Logic board. It also has jumpers to connect bias resistors to the RS-485 bus subnetworks.
33 -
34 34  [[image:1734105319233-615.png||data-xwiki-image-style-alignment="center" height="353" width="350"]]
35 35  
36 36  |**Parameter**|**Value**
... ... @@ -37,11 +37,10 @@
37 37  |Overall dimensions (length × width × height), mm|64 × 30 × 16
38 38  |Mounting dimensions (length × width), mm|57 × 23
39 39  |Mounting holes|M3
34 +|Header types|Molex series Mini-Fit
40 40  
41 -== X1 – header for communication with BMS Main board ==
36 +== X1 – header for communication with BMS Main ==
42 42  
43 -Receptacle Housing: Molex 39012040. Terminals: Molex 5556
44 -
45 45  [[image:1734105400608-295.png||data-xwiki-image-style-alignment="center" height="83" width="75"]]
46 46  
47 47  |**Pin**|**Name**|**Description**
... ... @@ -50,10 +50,8 @@
50 50  |**3**|**+5V**|Supply voltage 5V
51 51  |**4**|**GND1**|Ground
52 52  
53 -== X2 – header for communication with BMS Logic board ==
46 +== X2 – header for communication with BMS Logic ==
54 54  
55 -Receptacle Housing: Molex 39012040. Terminals: Molex 5556
56 -
57 57  [[image:1734105400608-295.png||data-xwiki-image-style-alignment="center" height="83" width="75"]]
58 58  