Summary

Details

Page properties
Parent
... ... @@ -1,1 +1,1 @@
1 -Battery management systems.BMS Mini.WebHome
1 +drafts.BMS Mini S.WebHome
Content
... ... @@ -15,15 +15,14 @@
15 15  
16 16  [[image:1733738313786-252.png||data-xwiki-image-style-alignment="center" height="150" width="545"]]
17 17  
18 -|(((
18 +| (((
19 19  **Parameter**
20 20  )))|**Value **
21 -|(((
21 +| (((
22 22  Overall dimensions (length × width × height), mm
23 23  )))|139.5 × 117 × 17
24 24  |Mounting dimensions (length × width), mm|130 × 111
25 25  |Mounting holes|M3
26 -|Headers X1, X3-X9 type|Molex series Micro-Fit
27 27  
28 28  == Headers ==
29 29  
... ... @@ -31,10 +31,8 @@
31 31  
32 32  [[image:1733738660900-622.png||data-xwiki-image-style-alignment="center" height="379" width="508"]]
33 33  
34 -=== Х1 – header for contactors ===
33 +=== Х1 – header for contactors. ===
35 35  
36 -Receptacle Housing: Molex 430251800. Terminals: Molex 43030
37 -
38 38  [[image:1733738660904-795.jpeg||data-xwiki-image-style-alignment="center" height="96" width="316"]]
39 39  
40 40  |**Pin**|**Name**|**Description**
... ... @@ -63,27 +63,16 @@
63 63  The load should be connected to +12V and OUTx pins. The feedback signal should be connected to FBx and GND pins. Below is an example of connecting the BMS to a contactor:
64 64  )))
65 65  
66 -[[image:1733738760833-185.png||data-xwiki-image-style-alignment="center" height="220" width="332"]]
63 +[[image:1733738760833-185.png||data-xwiki-image-style-alignment="center"]]
67 67  
68 68  === X2 – mini-USB connector. ===
69 69  
70 70  Mini0USB connector is used for configuring the BMS via ElectricDeviceMonito
71 71  
72 -=== X3 – header for discrete inputs and outputs signals ===
69 +=== X3 – header for discrete inputs and outputs signals. ===
73 73  
74 -(% class="wikigeneratedid" %)
75 -Receptacle Housing: Molex 430251600. Terminals: Molex 43030
71 +[[image:file:///C:/Users/INASIB~~1/AppData/Local/Temp/msohtmlclip1/01/clip_image003.emz]][[image:1733738860923-996.png||data-xwiki-image-style-alignment="center" height="90" width="283"]]
76 76  
77 -
78 -
79 -
80 -
81 -
82 -
83 -
84 -(% class="wikigeneratedid" %)
85 -[[image:1733738860923-996.png||data-xwiki-image-style-alignment="center" height="90" width="283"]]
86 -
87 87  |**Pin**|**Name**|**Description**
88 88  |**1**|**DIN1**|Discrete input 1 “dry contact” (+5V)
89 89  |**2**|**DIN2**|Discrete input 2 “dry contact” (+5V)
... ... @@ -102,10 +102,8 @@
102 102  |**15**|**GND**|Discrete output 3 (ground)
103 103  |**16**|**GND**|Discrete output 4 (ground)
104 104  
105 -=== Х4 – header for САN and RS485 interfaces ===
91 +=== Х4 – header for САN and RS485 interfaces. ===
106 106  
107 -Receptacle Housing: Molex 430250600. Terminals: Molex 43030
108 -
109 109  [[image:1733738660905-974.jpeg||data-xwiki-image-style-alignment="center" height="70" width="97"]]
110 110  
111 111  |**Pin**|**Name**|**Description**
... ... @@ -116,21 +116,16 @@
116 116  |**5**|**GND**|Isolated ground
117 117  |**6**|**CAN_H**|CAN-H line of the CAN bus
118 118  
119 -=== Х5 – header for ON/OFF button ===
103 +=== Х5 – header for ON/OFF button. ===
120 120  
121 -Receptacle Housing: Molex 430250200. Terminals: Molex 43030
105 +[[image:file:///C:/Users/INASIB~~1/AppData/Local/Temp/msohtmlclip1/01/clip_image005.emz]][[image:1733739076878-324.png||data-xwiki-image-style-alignment="center" height="70" width="41"]]
122 122  
123 -(% class="wikigeneratedid" %)
124 -[[image:1733739076878-324.png||data-xwiki-image-style-alignment="center" height="70" width="41"]]
125 -
126 126  |**Pin**|**Name**|**Description**
127 127  |**1**|**BTN**|Signal to turn on/off the BMS (“dry contact”, +3.3V)
128 128  |**2**|**GND**|Signal to turn on/off the BMS (“dry contact”, ground)
129 129  
130 -=== X6 – header for cells temperature sensors ===
111 +=== X6 – header for cells temperature sensors. ===
131 131  
132 -Receptacle Housing: Molex 430251200. Terminals: Molex 43030
133 -
134 134  [[image:1733738660906-697.png||data-xwiki-image-style-alignment="center" height="91" width="190"]]
135 135  
136 136  |**Pin**|**Name**|**Description**
... ... @@ -147,21 +147,10 @@
147 147  |**11**|**TEMP5**|Signal from the thermistor 5
148 148  |**12**|**TEMP6**|Signal from the thermistor 6
149 149  
150 -=== X7 - header for current sensor ===
129 +=== X7 - header for current sensor. ===
151 151  
152 -(% class="wikigeneratedid" %)
153 -Receptacle Housing: Molex 430250400. Terminals: Molex 43030
131 +[[image:file:///C:/Users/INASIB~~1/AppData/Local/Temp/msohtmlclip1/01/clip_image007.emz]][[image:1733739118831-618.png||data-xwiki-image-style-alignment="center" height="79" width="71"]]
154 154  
155 -
156 -
157 -
158 -
159 -
160 -
161 -
162 -(% class="wikigeneratedid" %)
163 -[[image:1733739118831-618.png||data-xwiki-image-style-alignment="center" height="79" width="71"]]
164 -
165 165  |**Pin**|**Name**|**Description**
166 166  |**1**|**+5V**|Supply voltage for a current sensor 5V, max 50 mA
167 167  |**2**|**GND**|Ground
... ... @@ -170,8 +170,6 @@
170 170  
171 171  === Х8 – header for battery cells ===
172 172  
173 -Receptacle Housing: Molex 430252000. Terminals: Molex 43030
174 -
175 175  [[image:1733738660908-107.jpeg||data-xwiki-image-style-alignment="center" height="83" width="291"]]
176 176  
177 177  |**Pin**|**Name**|**Description**
... ... @@ -198,8 +198,6 @@
198 198  
199 199  === Х9 – header to power the device ===
200 200  
201 -Receptacle Housing: Molex 436450200. Terminals: Molex 43030
202 -
203 203  [[image:1733738660910-242.png||data-xwiki-image-style-alignment="center" height="61" width="78"]]
204 204  
205 205  |**Pin**|**Name**|**Description**
... ... @@ -208,18 +208,18 @@
208 208  
209 209  (% class="box warningmessage" %)
210 210  (((
211 -**Attention! **The BMS Mini device is **galvanically connected** to the battery (the minus of the battery is the device ground). In view of this, when a BMS Wi-Fi or BMS GSM module is connected to the device, the antenna braid will also be galvanically connected to the battery (connected to the battery negative). It is recommended to** isolate the antenna cable from the battery case **to prevent negative potential from appearing on the case.
175 +**Attention! **The BMS Mini S device is **galvanically connected** to the battery (the minus of the battery is the device ground). In view of this, when a BMS Wi-Fi or BMS GSM module is connected to the device, the antenna braid will also be galvanically connected to the battery (connected to the battery negative). It is recommended to** isolate the antenna cable from the battery case **to prevent negative potential from appearing on the case.
212 212  )))
213 213  
214 214  === J1 – jumper for switching CAN bus terminal resistor ===
215 215  
216 -To connect the terminal resistor between the** CAN_H** and **CAN_L** lines, install the jumper J1 according to the following figure:
180 +To connect the terminal resistor between the** CAN_H** and **CAN_L** lines, install the jumper J1 according to the following figure:
217 217  
218 218  [[image:1733738660910-372.png||data-xwiki-image-style-alignment="center" height="85" width="162"]]
219 219  
220 220  === J2 – jumper for switching RS-485 terminal resistor ===
221 221  
222 -To connect the terminal resistor between the** RS485_A** and **RS485_B** lines, install the jumper J1 according to the following figure:
186 +To connect the terminal resistor between the** RS485_A** and **RS485_B** lines, install the jumper J1 according to the following figure:
223 223  
224 224  [[image:1733738660910-372.png||data-xwiki-image-style-alignment="center" height="85" width="162"]]
225 225  
... ... @@ -232,7 +232,7 @@
232 232  
233 233  Begin the connection with the negative line of the battery: the “C0“ is connected to the “B-“, then the first cell (C1) is connected, then the second (С2), etc. If not all inputs of the cells are used, then the remaining inputs are connected to the cell with the most potential.
234 234  
235 -[[image:1733738660912-678.png||data-xwiki-image-style-alignment="center" height="326" width="650"]]
199 +[[image:1733738660912-678.png||data-xwiki-image-style-alignment="center" height="474" width="945"]]
236 236  
237 237  (% class="box warningmessage" %)
238 238  (((