Last modified by Admin on 2025/03/18 12:50

From version 8.2
edited by Admin
on 2025/02/20 13:18
Change comment: There is no comment for this version
To version 13.1
edited by Admin
on 2025/03/18 12:19
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,6 +1,24 @@
1 1  (% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 2  = Installation and connection =
3 3  
4 +== Safety rules ==
5 +
6 +To perform the protection functions, the BMS must be able to disconnect the battery from the load and charger. To do this, at least one contactor able to break the load and charge circuits must be connected to the BMS.
7 +
8 +Before use, **configure the system**. Proper operation of the BMS is possible only if it is correctly configured.
9 +
10 +It is not recommended to use the system in batteries formed by several series of cells connected in parallel. To increase capacity, it is recommended to connect several cells in parallel groups, and then connect the groups in series.
11 +
12 +(% class="box warningmessage" %)
13 +(((
14 +The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools and appliances. To prevent the damage of device avoid electrostatic discharges while working with the battery.
15 +)))
16 +
17 +(% class="box errormessage" %)
18 +(((
19 +**The system is not designed to operate with batteries whose total voltage exceeds 80V.**
20 +)))
21 +
4 4  == Installation procedure ==
5 5  
6 6  The mounting area of the BMS Mini must be protected from mechanical particles (dust, dirt, large objects) and water. The BMS Mini is recommended to be placed close to the cells it controls, but away from high current circuits to reduce interference to measuring circuits and increase overall reliability of installation.
... ... @@ -23,7 +23,6 @@
23 23  )))|139.5 × 117 × 17
24 24  |Mounting dimensions (length × width), mm|130 × 111
25 25  |Mounting holes|M3
26 -|Headers X1, X3-X9 type|Molex series Micro-Fit
27 27  
28 28  == Headers ==
29 29  
... ... @@ -67,7 +67,7 @@
67 67  
68 68  === X2 – mini-USB connector. ===
69 69  
70 -Mini0USB connector is used for configuring the BMS via ElectricDeviceMonito
87 +Mini-USB connector is used for configuring the BMS via ElectricDeviceMonitor.
71 71  
72 72  === X3 – header for discrete inputs and outputs signals ===
73 73  
... ... @@ -170,6 +170,7 @@
170 170  
171 171  === Х8 – header for battery cells ===
172 172  
190 +Receptacle Housing: Molex 430252000. Terminals: Molex 43030
173 173  
174 174  [[image:1733738660908-107.jpeg||data-xwiki-image-style-alignment="center" height="83" width="291"]]
175 175  
... ... @@ -197,6 +197,8 @@
197 197  
198 198  === Х9 – header to power the device ===
199 199  
218 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030
219 +
200 200  [[image:1733738660910-242.png||data-xwiki-image-style-alignment="center" height="61" width="78"]]
201 201  
202 202  |**Pin**|**Name**|**Description**