Last modified by Admin on 2025/03/18 12:50

From version 6.2
edited by Admin
on 2024/12/23 16:06
Change comment: Update document after refactoring.
To version 3.1
edited by Admin
on 2024/12/09 10:40
Change comment: There is no comment for this version

Summary

Details

Page properties
Parent
... ... @@ -1,1 +1,1 @@
1 -Battery management systems.BMS Mini.WebHome
1 +drafts.BMS Mini 2.WebHome
Content
... ... @@ -60,7 +60,7 @@
60 60  The load should be connected to +12V and OUTx pins. The feedback signal should be connected to FBx and GND pins. Below is an example of connecting the BMS to a contactor:
61 61  )))
62 62  
63 -[[image:1733738760833-185.png||data-xwiki-image-style-alignment="center" height="220" width="332"]]
63 +[[image:1733738760833-185.png||data-xwiki-image-style-alignment="center"]]
64 64  
65 65  === X2 – mini-USB connector. ===
66 66  
... ... @@ -98,8 +98,10 @@
98 98  |**5**|**GND**|Isolated ground
99 99  |**6**|**CAN_H**|CAN-H line of the CAN bus
100 100  
101 -=== Х5 – header for ON/OFF button.[[image:1733739076878-324.png||data-xwiki-image-style-alignment="center" height="70" width="41"]] ===
101 +=== Х5 – header for ON/OFF button. ===
102 102  
103 +[[image:file:///C:/Users/INASIB~~1/AppData/Local/Temp/msohtmlclip1/01/clip_image005.emz]][[image:1733739076878-324.png||data-xwiki-image-style-alignment="center" height="70" width="41"]]
104 +
103 103  |**Pin**|**Name**|**Description**
104 104  |**1**|**BTN**|Signal to turn on/off the BMS (“dry contact”, +3.3V)
105 105  |**2**|**GND**|Signal to turn on/off the BMS (“dry contact”, ground)
... ... @@ -122,8 +122,10 @@
122 122  |**11**|**TEMP5**|Signal from the thermistor 5
123 123  |**12**|**TEMP6**|Signal from the thermistor 6
124 124  
125 -=== X7 - header for current sensor.[[image:1733739118831-618.png||data-xwiki-image-style-alignment="center" height="79" width="71"]] ===
127 +=== X7 - header for current sensor. ===
126 126  
129 +[[image:file:///C:/Users/INASIB~~1/AppData/Local/Temp/msohtmlclip1/01/clip_image007.emz]][[image:1733739118831-618.png||data-xwiki-image-style-alignment="center" height="79" width="71"]]
130 +
127 127  |**Pin**|**Name**|**Description**
128 128  |**1**|**+5V**|Supply voltage for a current sensor 5V, max 50 mA
129 129  |**2**|**GND**|Ground
... ... @@ -166,7 +166,7 @@
166 166  
167 167  (% class="box warningmessage" %)
168 168  (((
169 -**Attention! **The BMS Mini device is **galvanically connected** to the battery (the minus of the battery is the device ground). In view of this, when a BMS Wi-Fi or BMS GSM module is connected to the device, the antenna braid will also be galvanically connected to the battery (connected to the battery negative). It is recommended to** isolate the antenna cable from the battery case **to prevent negative potential from appearing on the case.
173 +**Attention! **The BMS Mini S device is **galvanically connected** to the battery (the minus of the battery is the device ground). In view of this, when a BMS Wi-Fi or BMS GSM module is connected to the device, the antenna braid will also be galvanically connected to the battery (connected to the battery negative). It is recommended to** isolate the antenna cable from the battery case **to prevent negative potential from appearing on the case.
170 170  )))
171 171  
172 172  === J1 – jumper for switching CAN bus terminal resistor ===