Last modified by Admin on 2025/03/18 12:50

From version 4.1
edited by Admin
on 2024/12/09 10:42
Change comment: There is no comment for this version
To version 2.2
edited by Admin
on 2024/12/09 10:18
Change comment: Update document after refactoring.

Summary

Details

Page properties
Content
... ... @@ -60,14 +60,16 @@
60 60  The load should be connected to +12V and OUTx pins. The feedback signal should be connected to FBx and GND pins. Below is an example of connecting the BMS to a contactor:
61 61  )))
62 62  
63 -[[image:1733738760833-185.png||data-xwiki-image-style-alignment="center" height="220" width="332"]]
63 +[[image:1733738760833-185.png||data-xwiki-image-style-alignment="center"]]
64 64  
65 65  === X2 – mini-USB connector. ===
66 66  
67 67  Mini0USB connector is used for configuring the BMS via ElectricDeviceMonito
68 68  
69 -=== X3 – header for discrete inputs and outputs signals.[[image:1733738860923-996.png||data-xwiki-image-style-alignment="center" height="90" width="283"]] ===
69 +=== X3 – header for discrete inputs and outputs signals. ===
70 70  
71 +[[image:file:///C:/Users/INASIB~~1/AppData/Local/Temp/msohtmlclip1/01/clip_image003.emz]][[image:1733738860923-996.png||data-xwiki-image-style-alignment="center" height="90" width="283"]]
72 +
71 71  |**Pin**|**Name**|**Description**
72 72  |**1**|**DIN1**|Discrete input 1 “dry contact” (+5V)
73 73  |**2**|**DIN2**|Discrete input 2 “dry contact” (+5V)
... ... @@ -98,8 +98,10 @@
98 98  |**5**|**GND**|Isolated ground
99 99  |**6**|**CAN_H**|CAN-H line of the CAN bus
100 100  
101 -=== Х5 – header for ON/OFF button.[[image:1733739076878-324.png||data-xwiki-image-style-alignment="center" height="70" width="41"]] ===
103 +=== Х5 – header for ON/OFF button. ===
102 102  
105 +[[image:file:///C:/Users/INASIB~~1/AppData/Local/Temp/msohtmlclip1/01/clip_image005.emz]][[image:1733739076878-324.png||data-xwiki-image-style-alignment="center" height="70" width="41"]]
106 +
103 103  |**Pin**|**Name**|**Description**
104 104  |**1**|**BTN**|Signal to turn on/off the BMS (“dry contact”, +3.3V)
105 105  |**2**|**GND**|Signal to turn on/off the BMS (“dry contact”, ground)
... ... @@ -122,8 +122,10 @@
122 122  |**11**|**TEMP5**|Signal from the thermistor 5
123 123  |**12**|**TEMP6**|Signal from the thermistor 6
124 124  
125 -=== X7 - header for current sensor.[[image:1733739118831-618.png||data-xwiki-image-style-alignment="center" height="79" width="71"]] ===
129 +=== X7 - header for current sensor. ===
126 126  
131 +[[image:file:///C:/Users/INASIB~~1/AppData/Local/Temp/msohtmlclip1/01/clip_image007.emz]][[image:1733739118831-618.png||data-xwiki-image-style-alignment="center" height="79" width="71"]]
132 +
127 127  |**Pin**|**Name**|**Description**
128 128  |**1**|**+5V**|Supply voltage for a current sensor 5V, max 50 mA
129 129  |**2**|**GND**|Ground