Last modified by Admin on 2025/03/18 12:50

From version 3.1
edited by Admin
on 2024/12/09 10:40
Change comment: There is no comment for this version
To version 10.1
edited by Admin
on 2025/02/27 12:28
Change comment: There is no comment for this version

Summary

Details

Page properties
Parent
... ... @@ -1,1 +1,1 @@
1 -drafts.BMS Mini 2.WebHome
1 +Battery management systems.BMS Mini.WebHome
Content
... ... @@ -30,8 +30,10 @@
30 30  
31 31  [[image:1733738660900-622.png||data-xwiki-image-style-alignment="center" height="379" width="508"]]
32 32  
33 -=== Х1 – header for contactors. ===
33 +=== Х1 – header for contactors ===
34 34  
35 +Receptacle Housing: Molex 430251800. Terminals: Molex 43030
36 +
35 35  [[image:1733738660904-795.jpeg||data-xwiki-image-style-alignment="center" height="96" width="316"]]
36 36  
37 37  |**Pin**|**Name**|**Description**
... ... @@ -60,14 +60,27 @@
60 60  The load should be connected to +12V and OUTx pins. The feedback signal should be connected to FBx and GND pins. Below is an example of connecting the BMS to a contactor:
61 61  )))
62 62  
63 -[[image:1733738760833-185.png||data-xwiki-image-style-alignment="center"]]
65 +[[image:1733738760833-185.png||data-xwiki-image-style-alignment="center" height="220" width="332"]]
64 64  
65 65  === X2 – mini-USB connector. ===
66 66  
67 67  Mini0USB connector is used for configuring the BMS via ElectricDeviceMonito
68 68  
69 -=== X3 – header for discrete inputs and outputs signals.[[image:1733738860923-996.png||data-xwiki-image-style-alignment="center" height="90" width="283"]] ===
71 +=== X3 – header for discrete inputs and outputs signals ===
70 70  
73 +(% class="wikigeneratedid" %)
74 +Receptacle Housing: Molex 430251600. Terminals: Molex 43030
75 +
76 +
77 +
78 +
79 +
80 +
81 +
82 +
83 +(% class="wikigeneratedid" %)
84 +[[image:1733738860923-996.png||data-xwiki-image-style-alignment="center" height="90" width="283"]]
85 +
71 71  |**Pin**|**Name**|**Description**
72 72  |**1**|**DIN1**|Discrete input 1 “dry contact” (+5V)
73 73  |**2**|**DIN2**|Discrete input 2 “dry contact” (+5V)
... ... @@ -86,8 +86,10 @@
86 86  |**15**|**GND**|Discrete output 3 (ground)
87 87  |**16**|**GND**|Discrete output 4 (ground)
88 88  
89 -=== Х4 – header for САN and RS485 interfaces. ===
104 +=== Х4 – header for САN and RS485 interfaces ===
90 90  
106 +Receptacle Housing: Molex 430250600. Terminals: Molex 43030
107 +
91 91  [[image:1733738660905-974.jpeg||data-xwiki-image-style-alignment="center" height="70" width="97"]]
92 92  
93 93  |**Pin**|**Name**|**Description**
... ... @@ -98,16 +98,21 @@
98 98  |**5**|**GND**|Isolated ground
99 99  |**6**|**CAN_H**|CAN-H line of the CAN bus
100 100  
101 -=== Х5 – header for ON/OFF button. ===
118 +=== Х5 – header for ON/OFF button ===
102 102  
103 -[[image:file:///C:/Users/INASIB~~1/AppData/Local/Temp/msohtmlclip1/01/clip_image005.emz]][[image:1733739076878-324.png||data-xwiki-image-style-alignment="center" height="70" width="41"]]
120 +Receptacle Housing: Molex 430250200. Terminals: Molex 43030
104 104  
122 +(% class="wikigeneratedid" %)
123 +[[image:1733739076878-324.png||data-xwiki-image-style-alignment="center" height="70" width="41"]]
124 +
105 105  |**Pin**|**Name**|**Description**
106 106  |**1**|**BTN**|Signal to turn on/off the BMS (“dry contact”, +3.3V)
107 107  |**2**|**GND**|Signal to turn on/off the BMS (“dry contact”, ground)
108 108  
109 -=== X6 – header for cells temperature sensors. ===
129 +=== X6 – header for cells temperature sensors ===
110 110  
131 +Receptacle Housing: Molex 430251200. Terminals: Molex 43030
132 +
111 111  [[image:1733738660906-697.png||data-xwiki-image-style-alignment="center" height="91" width="190"]]
112 112  
113 113  |**Pin**|**Name**|**Description**
... ... @@ -124,10 +124,21 @@
124 124  |**11**|**TEMP5**|Signal from the thermistor 5
125 125  |**12**|**TEMP6**|Signal from the thermistor 6
126 126  
127 -=== X7 - header for current sensor. ===
149 +=== X7 - header for current sensor ===
128 128  
129 -[[image:file:///C:/Users/INASIB~~1/AppData/Local/Temp/msohtmlclip1/01/clip_image007.emz]][[image:1733739118831-618.png||data-xwiki-image-style-alignment="center" height="79" width="71"]]
151 +(% class="wikigeneratedid" %)
152 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030
130 130  
154 +
155 +
156 +
157 +
158 +
159 +
160 +
161 +(% class="wikigeneratedid" %)
162 +[[image:1733739118831-618.png||data-xwiki-image-style-alignment="center" height="79" width="71"]]
163 +
131 131  |**Pin**|**Name**|**Description**
132 132  |**1**|**+5V**|Supply voltage for a current sensor 5V, max 50 mA
133 133  |**2**|**GND**|Ground
... ... @@ -136,6 +136,8 @@
136 136  
137 137  === Х8 – header for battery cells ===
138 138  
172 +Receptacle Housing: Molex 430252000. Terminals: Molex 43030
173 +
139 139  [[image:1733738660908-107.jpeg||data-xwiki-image-style-alignment="center" height="83" width="291"]]
140 140  
141 141  |**Pin**|**Name**|**Description**
... ... @@ -162,6 +162,8 @@
162 162  
163 163  === Х9 – header to power the device ===
164 164  
200 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030
201 +
165 165  [[image:1733738660910-242.png||data-xwiki-image-style-alignment="center" height="61" width="78"]]
166 166  
167 167  |**Pin**|**Name**|**Description**
... ... @@ -170,7 +170,7 @@
170 170  
171 171  (% class="box warningmessage" %)
172 172  (((
173 -**Attention! **The BMS Mini S device is **galvanically connected** to the battery (the minus of the battery is the device ground). In view of this, when a BMS Wi-Fi or BMS GSM module is connected to the device, the antenna braid will also be galvanically connected to the battery (connected to the battery negative). It is recommended to** isolate the antenna cable from the battery case **to prevent negative potential from appearing on the case.
210 +**Attention! **The BMS Mini device is **galvanically connected** to the battery (the minus of the battery is the device ground). In view of this, when a BMS Wi-Fi or BMS GSM module is connected to the device, the antenna braid will also be galvanically connected to the battery (connected to the battery negative). It is recommended to** isolate the antenna cable from the battery case **to prevent negative potential from appearing on the case.
174 174  )))
175 175  
176 176  === J1 – jumper for switching CAN bus terminal resistor ===