Changes for page 2. Installation and connection
Last modified by Admin on 2025/03/18 12:50
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -drafts.BMS Mini S.WebHome1 +drafts.BMS Mini 2.WebHome - Content
-
... ... @@ -60,16 +60,14 @@ 60 60 The load should be connected to +12V and OUTx pins. The feedback signal should be connected to FBx and GND pins. Below is an example of connecting the BMS to a contactor: 61 61 ))) 62 62 63 -[[image:1733738760833-185.png||data-xwiki-image-style-alignment="center"]] 63 +[[image:1733738760833-185.png||data-xwiki-image-style-alignment="center" height="220" width="332"]] 64 64 65 65 === X2 – mini-USB connector. === 66 66 67 67 Mini0USB connector is used for configuring the BMS via ElectricDeviceMonito 68 68 69 -=== X3 – header for discrete inputs and outputs signals. === 69 +=== X3 – header for discrete inputs and outputs signals.[[image:1733738860923-996.png||data-xwiki-image-style-alignment="center" height="90" width="283"]] === 70 70 71 -[[image:file:///C:/Users/INASIB~~1/AppData/Local/Temp/msohtmlclip1/01/clip_image003.emz]][[image:1733738860923-996.png||data-xwiki-image-style-alignment="center" height="90" width="283"]] 72 - 73 73 |**Pin**|**Name**|**Description** 74 74 |**1**|**DIN1**|Discrete input 1 “dry contact” (+5V) 75 75 |**2**|**DIN2**|Discrete input 2 “dry contact” (+5V) ... ... @@ -100,10 +100,8 @@ 100 100 |**5**|**GND**|Isolated ground 101 101 |**6**|**CAN_H**|CAN-H line of the CAN bus 102 102 103 -=== Х5 – header for ON/OFF button. === 101 +=== Х5 – header for ON/OFF button.[[image:1733739076878-324.png||data-xwiki-image-style-alignment="center" height="70" width="41"]] === 104 104 105 -[[image:file:///C:/Users/INASIB~~1/AppData/Local/Temp/msohtmlclip1/01/clip_image005.emz]][[image:1733739076878-324.png||data-xwiki-image-style-alignment="center" height="70" width="41"]] 106 - 107 107 |**Pin**|**Name**|**Description** 108 108 |**1**|**BTN**|Signal to turn on/off the BMS (“dry contact”, +3.3V) 109 109 |**2**|**GND**|Signal to turn on/off the BMS (“dry contact”, ground) ... ... @@ -126,10 +126,8 @@ 126 126 |**11**|**TEMP5**|Signal from the thermistor 5 127 127 |**12**|**TEMP6**|Signal from the thermistor 6 128 128 129 -=== X7 - header for current sensor. === 125 +=== X7 - header for current sensor.[[image:1733739118831-618.png||data-xwiki-image-style-alignment="center" height="79" width="71"]] === 130 130 131 -[[image:file:///C:/Users/INASIB~~1/AppData/Local/Temp/msohtmlclip1/01/clip_image007.emz]][[image:1733739118831-618.png||data-xwiki-image-style-alignment="center" height="79" width="71"]] 132 - 133 133 |**Pin**|**Name**|**Description** 134 134 |**1**|**+5V**|Supply voltage for a current sensor 5V, max 50 mA 135 135 |**2**|**GND**|Ground