Last modified by Admin on 2025/05/28 15:41

From version 9.1
edited by Admin
on 2025/03/18 12:18
Change comment: There is no comment for this version
To version 5.1
edited by Admin
on 2025/02/27 12:25
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -10,11 +10,9 @@
10 10  |Battery voltage, V|(% style="width:230px" %)14 to 78
11 11  |(((
12 12  Current consumption @48 V, mA (maximum):
13 -
14 -* work (no load)
15 -* standby
13 + work (no load)
14 + standby
16 16  )))|(% style="width:230px" %)(((
17 -
18 18  
19 19  30
20 20  0.2
... ... @@ -38,7 +38,6 @@
38 38  |Dimensions (length × width × height), mm|(% style="width:230px" %)140 × 117 × 17
39 39  |Weight, g|(% style="width:230px" %)240 ± 5
40 40  |Operating temperature range, °С|(% style="width:230px" %)-40 to +85
41 -|Headers X1, X3-X9 type|Molex series Micro-Fit
42 42  
43 43  == Overall and mounting dimensions ==
44 44  
... ... @@ -50,4 +50,13 @@
50 50  
51 51  [[image:1733738121167-480.png]]
52 52  
50 +== Safety rules ==
51 +
52 +The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools, and appliances.
53 +
54 +(% class="box errormessage" %)
55 +(((
56 +**The system is not designed to work with batteries with total voltage more than 80 volts.**
57 +)))
58 +
53 53