Last modified by Admin on 2025/05/13 17:17

From version 9.1
edited by Admin
on 2025/03/18 12:18
Change comment: There is no comment for this version
To version 4.1
edited by Admin
on 2024/12/23 16:01
Change comment: There is no comment for this version

Summary

Details

Page properties
Parent
... ... @@ -1,1 +1,1 @@
1 -Battery management systems.BMS Mini.WebHome
1 +Battery management systems.BMS Mini 2.WebHome
Content
... ... @@ -11,12 +11,14 @@
11 11  |(((
12 12  Current consumption @48 V, mA (maximum):
13 13  
14 -* work (no load)
15 -* standby
14 + work (no load)
15 +
16 + standby
16 16  )))|(% style="width:230px" %)(((
17 17  
18 18  
19 19  30
21 +
20 20  0.2
21 21  )))
22 22  |Number of cells|(% style="width:230px" %)6 to 18
... ... @@ -35,10 +35,10 @@
35 35  |Discrete outputs current, mA (maximum)|(% style="width:230px" %)100
36 36  |Type of the current sensor|(% style="width:230px" %)Hall-Effect sensor, bidirectional, (LEM series: HASS, HTFS, DHAB)
37 37  |Wired interfaces|(% style="width:230px" %)1xCAN / 1xRS-485 / 1xUSB
40 +|Wireless interfaces|(% style="width:230px" %)Wi-Fi (optional)
38 38  |Dimensions (length × width × height), mm|(% style="width:230px" %)140 × 117 × 17
39 39  |Weight, g|(% style="width:230px" %)240 ± 5
40 40  |Operating temperature range, °С|(% style="width:230px" %)-40 to +85
41 -|Headers X1, X3-X9 type|Molex series Micro-Fit
42 42  
43 43  == Overall and mounting dimensions ==
44 44  
... ... @@ -50,4 +50,13 @@
50 50  
51 51  [[image:1733738121167-480.png]]
52 52  
55 +== Safety rules ==
56 +
57 +The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools, and appliances.
58 +
59 +(% class="box errormessage" %)
60 +(((
61 +**The system is not designed to work with batteries with total voltage more than 80 volts.**
62 +)))
63 +
53 53