Changes for page 1. Technical specifications
Last modified by Admin on 2025/05/13 17:17
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -5,40 +5,36 @@ 5 5 6 6 == Specifications == 7 7 8 -(% style="width:6 24px" %)9 -|**Parameter**|(% style="width:23 0px" %)**Value**10 -|Battery voltage, V|(% style="width:23 0px" %)14 to 7811 -|((( 8 +(% style="width:642px" %) 9 +|(% style="width:402px" %)**Parameter**|(% style="width:237px" %)**Value** 10 +|(% style="width:402px" %)Battery voltage, V|(% style="width:237px" %)14 to 78 11 +|(% style="width:402px" %)((( 12 12 Current consumption @48 V, mA (maximum): 13 13 14 14 * work (no load) 15 15 * standby 16 -)))|(% style="width:23 0px" %)(((16 +)))|(% style="width:237px" %)((( 17 17 18 18 19 19 30 20 20 0.2 21 21 ))) 22 -|Number of cells|(% style="width:230px" %)6 to 18 23 -|Cell balancing type|(% style="width:230px" %)Passive 24 -|Cell balancing current, mA, @ 4.2 V|(% style="width:230px" %)220 25 -|Cell voltage measurement error, V|(% style="width:230px" %)0.004 26 -|Cell temperature measurement error, °С|(% style="width:230px" %)2 27 -|Output voltage of the internal DC/DC converter, V|(% style="width:230px" %)12 ± 1 28 -|Output current of the internal DC/DC converter, A (maximum)|(% style="width:230px" %)3 29 -|Number of MOSFETs (to drive power contactors)|(% style="width:230px" %)4 30 -|MOSFETs output voltage, V (maximum)|(% style="width:230px" %)100 31 -|MOSFETs output current, A (maximum)|(% style="width:230px" %)5 32 -|Number of discrete inputs (dry contact)|(% style="width:230px" %)4 33 -|Number of discrete outputs|(% style="width:230px" %)4 34 -|Discrete outputs voltage, V (typical)|(% style="width:230px" %)5 35 -|Discrete outputs current, mA (maximum)|(% style="width:230px" %)100 36 -|Type of the current sensor|(% style="width:230px" %)Hall-Effect sensor, bidirectional, (LEM series: HASS, HTFS, DHAB) 37 -|Wired interfaces|(% style="width:230px" %)1xCAN / 1xRS-485 / 1xUSB 38 -|Dimensions (length × width × height), mm|(% style="width:230px" %)140 × 117 × 17 39 -|Weight, g|(% style="width:230px" %)240 ± 5 40 -|Operating temperature range, °С|(% style="width:230px" %)-40 to +85 41 -|Headers X1, X3-X9 type|Molex series Micro-Fit 22 +|(% style="width:402px" %)Number of cells|(% style="width:237px" %)6 to 18 23 +|(% style="width:402px" %)Cell balancing type|(% style="width:237px" %)Passive 24 +|(% style="width:402px" %)Cell balancing current, mA, @ 4.2 V|(% style="width:237px" %)220 25 +|(% style="width:402px" %)Cell voltage measurement error, V|(% style="width:237px" %)0.004 26 +|(% style="width:402px" %)Cell temperature measurement error, °С|(% style="width:237px" %)2 27 +|(% style="width:402px" %)Output voltage of the internal DC/DC converter, V|(% style="width:237px" %)12 ± 1 28 +|(% style="width:402px" %)Output current of the internal DC/DC converter, A (maximum)|(% style="width:237px" %)3 29 +|(% style="width:402px" %)Number of programmable MOSFETs for contactors (100V, 5A)|(% style="width:237px" %)4 30 +|(% style="width:402px" %)Number of programmable discrete inputs (dry contact)|(% style="width:237px" %)4 31 +|(% style="width:402px" %)Number of programmable discrete outputs (5V, total 100mA)|(% style="width:237px" %)4 32 +|(% style="width:402px" %)Type of the current sensor|(% style="width:237px" %)Hall-Effect sensor, bidirectional, (LEM series: HASS, HTFS, DHAB) 33 +|(% style="width:402px" %)Wired interfaces|(% style="width:237px" %)1xCAN / 1xRS-485 / 1xUSB 34 +|(% style="width:402px" %)Dimensions (length × width × height), mm|(% style="width:237px" %)140 × 117 × 17 35 +|(% style="width:402px" %)Weight, g|(% style="width:237px" %)240 ± 5 36 +|(% style="width:402px" %)Operating temperature range, °С|(% style="width:237px" %)-40 to +85 37 +|(% style="width:402px" %)Headers X1, X3-X9 type|(% style="width:237px" %)Molex series Micro-Fit 42 42 43 43 == Overall and mounting dimensions == 44 44 ... ... @@ -50,13 +50,4 @@ 50 50 51 51 [[image:1733738121167-480.png]] 52 52 53 -== Safety rules == 54 - 55 -The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools, and appliances. 56 - 57 -(% class="box errormessage" %) 58 -((( 59 -**The system is not designed to work with batteries with total voltage more than 80 volts.** 60 -))) 61 - 62 62