Last modified by Admin on 2025/05/13 17:17

From version 8.1
edited by Admin
on 2025/02/27 12:28
Change comment: There is no comment for this version
To version 10.1
edited by Admin
on 2025/05/06 16:34
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -24,15 +24,11 @@
24 24  |Cell balancing current, mA, @ 4.2 V|(% style="width:230px" %)220
25 25  |Cell voltage measurement error, V|(% style="width:230px" %)0.004
26 26  |Cell temperature measurement error, °С|(% style="width:230px" %)2
27 -|Output voltage of the internal DC/DC converter, V|(% style="width:230px" %)12 ± 1
28 -|Output current of the internal DC/DC converter, A (maximum)|(% style="width:230px" %)3
29 -|Number of MOSFETs (to drive power contactors)|(% style="width:230px" %)4
30 -|MOSFETs output voltage, V (maximum)|(% style="width:230px" %)100
31 -|MOSFETs output current, A (maximum)|(% style="width:230px" %)5
32 -|Number of discrete inputs (dry contact)|(% style="width:230px" %)4
33 -|Number of discrete outputs|(% style="width:230px" %)4
34 -|Discrete outputs voltage, V (typical)|(% style="width:230px" %)5
35 -|Discrete outputs current, mA (maximum)|(% style="width:230px" %)100
27 +|Output voltage of the internal DC/DC converter, V|12 ± 1
28 +|Output current of the internal DC/DC converter, A (maximum)|3
29 +|Number of programmable MOSFETs for contactors (100V, 5A)|4
30 +|Number of programmable discrete inputs (dry contact)|4
31 +|Number of programmable discrete outputs (5V, total 100mA)|4
36 36  |Type of the current sensor|(% style="width:230px" %)Hall-Effect sensor, bidirectional, (LEM series: HASS, HTFS, DHAB)
37 37  |Wired interfaces|(% style="width:230px" %)1xCAN / 1xRS-485 / 1xUSB
38 38  |Dimensions (length × width × height), mm|(% style="width:230px" %)140 × 117 × 17
... ... @@ -50,13 +50,4 @@
50 50  
51 51  [[image:1733738121167-480.png]]
52 52  
53 -== Safety rules ==
54 -
55 -The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools, and appliances.
56 -
57 -(% class="box errormessage" %)
58 -(((
59 -**The system is not designed to work with batteries with total voltage more than 80 volts.**
60 -)))
61 -
62 62