Changes for page 1. Technical specifications
Last modified by Admin on 2025/05/13 17:17
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -5,37 +5,38 @@ 5 5 6 6 == Specifications == 7 7 8 -(% style="width:6 24px" %)9 -|**Parameter**|(% style="width:23 0px" %)**Value**10 -|Battery voltage, V|(% style="width:23 0px" %)14 to 7811 -|((( 8 +(% style="width:642px" %) 9 +|(% style="width:402px" %)**Parameter**|(% style="width:237px" %)**Value** 10 +|(% style="width:402px" %)Battery voltage, V|(% style="width:237px" %)14 to 78 11 +|(% style="width:402px" %)((( 12 12 Current consumption @48 V, mA (maximum): 13 - work (no load) 14 - standby 15 -)))|(% style="width:230px" %)((( 16 16 14 +* work (no load) 15 +* standby 16 +)))|(% style="width:237px" %)((( 17 + 18 + 17 17 30 18 18 0.2 19 19 ))) 20 -|Number of cells|(% style="width:230px" %)6 to 18 21 -|Cell balancing type|(% style="width:230px" %)Passive 22 -|Cell balancing current, mA, @ 4.2 V|(% style="width:230px" %)220 23 -|Cell voltage measurement error, V|(% style="width:230px" %)0.004 24 -|Cell temperature measurement error, °С|(% style="width:230px" %)2 25 -|Output voltage of the internal DC/DC converter, V|(% style="width:230px" %)12 ± 1 26 -|Output current of the internal DC/DC converter, A (maximum)|(% style="width:230px" %)3 27 -|Number of MOSFETs (to drive power contactors)|(% style="width:230px" %)4 28 -|MOSFETs output voltage, V (maximum)|(% style="width:230px" %)100 29 -|MOSFETs output current, A (maximum)|(% style="width:230px" %)5 30 -|Number of discrete inputs (dry contact)|(% style="width:230px" %)4 31 -|Number of discrete outputs|(% style="width:230px" %)4 32 -|Discrete outputs voltage, V (typical)|(% style="width:230px" %)5 33 -|Discrete outputs current, mA (maximum)|(% style="width:230px" %)100 34 -|Type of the current sensor|(% style="width:230px" %)Hall-Effect sensor, bidirectional, (LEM series: HASS, HTFS, DHAB) 35 -|Wired interfaces|(% style="width:230px" %)1xCAN / 1xRS-485 / 1xUSB 36 -|Dimensions (length × width × height), mm|(% style="width:230px" %)140 × 117 × 17 37 -|Weight, g|(% style="width:230px" %)240 ± 5 38 -|Operating temperature range, °С|(% style="width:230px" %)-40 to +85 22 +|(% style="width:402px" %)Number of cells|(% style="width:237px" %)6 to 18 23 +|(% style="width:402px" %)Cell balancing type|(% style="width:237px" %)Passive 24 +|(% style="width:402px" %)Cell balancing current, mA, @ 4.2 V|(% style="width:237px" %)220 25 +|(% style="width:402px" %)Cell voltage measurement error, V|(% style="width:237px" %)0.004 26 +|(% style="width:402px" %)Cell temperature measurement error, °С|(% style="width:237px" %)2 27 +|(% style="width:402px" %)Output voltage of the internal DC/DC converter, V|(% style="width:237px" %)12 ± 1 28 +|(% style="width:402px" %)Output current of the internal DC/DC converter, A (maximum)|(% style="width:237px" %)3 29 +|(% style="width:402px" %)Number of programmable MOSFETs for contactors (100V, 5A)|(% style="width:237px" %)4 30 +|(% style="width:402px" %)Number of programmable discrete inputs (dry contact)|(% style="width:237px" %)4 31 +|(% style="width:402px" %)Number of programmable discrete outputs (5V, total 100mA)|(% style="width:237px" %)4 32 +|(% style="width:402px" %)Type of the current sensor|(% style="width:237px" %)Hall-Effect sensor, bidirectional, (LEM series: HASS, HTFS, DHAB) 33 +|(% style="width:402px" %)Wired interfaces|(% style="width:237px" %)1xCAN / 1xRS-485 / 1xUSB 34 +|CAN output voltage, V|5.0 ± 0.5 35 +|CAN output current, mA (maximum)|400 36 +|(% style="width:402px" %)Dimensions (length × width × height), mm|(% style="width:237px" %)140 × 117 × 17 37 +|(% style="width:402px" %)Weight, g|(% style="width:237px" %)240 ± 5 38 +|(% style="width:402px" %)Operating temperature range, °С|(% style="width:237px" %)-40 to +85 39 +|(% style="width:402px" %)Headers X1, X3-X9 type|(% style="width:237px" %)Molex series Micro-Fit 39 39 40 40 == Overall and mounting dimensions == 41 41 ... ... @@ -47,13 +47,4 @@ 47 47 48 48 [[image:1733738121167-480.png]] 49 49 50 -== Safety rules == 51 - 52 -The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools, and appliances. 53 - 54 -(% class="box errormessage" %) 55 -((( 56 -**The system is not designed to work with batteries with total voltage more than 80 volts.** 57 -))) 58 - 59 59
- 1746624836334-361.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +36.2 KB - Content