Changes for page 1. Technical specifications
Last modified by Admin on 2025/05/28 15:41
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -10,9 +10,11 @@ 10 10 |Battery voltage, V|(% style="width:230px" %)14 to 78 11 11 |((( 12 12 Current consumption @48 V, mA (maximum): 13 - work (no load) 14 - standby 13 + 14 +* work (no load) 15 +* standby 15 15 )))|(% style="width:230px" %)((( 17 + 16 16 17 17 30 18 18 0.2 ... ... @@ -22,20 +22,17 @@ 22 22 |Cell balancing current, mA, @ 4.2 V|(% style="width:230px" %)220 23 23 |Cell voltage measurement error, V|(% style="width:230px" %)0.004 24 24 |Cell temperature measurement error, °С|(% style="width:230px" %)2 25 -|Output voltage of the internal DC/DC converter, V|(% style="width:230px" %)12 ± 1 26 -|Output current of the internal DC/DC converter, A (maximum)|(% style="width:230px" %)3 27 -|Number of MOSFETs (to drive power contactors)|(% style="width:230px" %)4 28 -|MOSFETs output voltage, V (maximum)|(% style="width:230px" %)100 29 -|MOSFETs output current, A (maximum)|(% style="width:230px" %)5 30 -|Number of discrete inputs (dry contact)|(% style="width:230px" %)4 31 -|Number of discrete outputs|(% style="width:230px" %)4 32 -|Discrete outputs voltage, V (typical)|(% style="width:230px" %)5 33 -|Discrete outputs current, mA (maximum)|(% style="width:230px" %)100 27 +|Output voltage of the internal DC/DC converter, V|12 ± 1 28 +|Output current of the internal DC/DC converter, A (maximum)|3 29 +|Number of programmable MOSFETs for contactors (100V, 5A)|4 30 +|Number of programmable discrete inputs (dry contact)|4 31 +|Number of programmable discrete outputs (5V, total 100mA)|4 34 34 |Type of the current sensor|(% style="width:230px" %)Hall-Effect sensor, bidirectional, (LEM series: HASS, HTFS, DHAB) 35 35 |Wired interfaces|(% style="width:230px" %)1xCAN / 1xRS-485 / 1xUSB 36 36 |Dimensions (length × width × height), mm|(% style="width:230px" %)140 × 117 × 17 37 37 |Weight, g|(% style="width:230px" %)240 ± 5 38 38 |Operating temperature range, °С|(% style="width:230px" %)-40 to +85 37 +|Headers X1, X3-X9 type|Molex series Micro-Fit 39 39 40 40 == Overall and mounting dimensions == 41 41 ... ... @@ -47,13 +47,4 @@ 47 47 48 48 [[image:1733738121167-480.png]] 49 49 50 -== Safety rules == 51 - 52 -The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools, and appliances. 53 - 54 -(% class="box errormessage" %) 55 -((( 56 -**The system is not designed to work with batteries with total voltage more than 80 volts.** 57 -))) 58 - 59 59