Last modified by Admin on 2025/05/13 17:17

From version 4.1
edited by Admin
on 2024/12/23 16:01
Change comment: There is no comment for this version
To version 10.1
edited by Admin
on 2025/05/06 16:34
Change comment: There is no comment for this version

Summary

Details

Page properties
Parent
... ... @@ -1,1 +1,1 @@
1 -Battery management systems.BMS Mini 2.WebHome
1 +Battery management systems.BMS Mini.WebHome
Content
... ... @@ -11,14 +11,12 @@
11 11  |(((
12 12  Current consumption @48 V, mA (maximum):
13 13  
14 - work (no load)
15 -
16 - standby
14 +* work (no load)
15 +* standby
17 17  )))|(% style="width:230px" %)(((
18 18  
19 19  
20 20  30
21 -
22 22  0.2
23 23  )))
24 24  |Number of cells|(% style="width:230px" %)6 to 18
... ... @@ -26,21 +26,17 @@
26 26  |Cell balancing current, mA, @ 4.2 V|(% style="width:230px" %)220
27 27  |Cell voltage measurement error, V|(% style="width:230px" %)0.004
28 28  |Cell temperature measurement error, °С|(% style="width:230px" %)2
29 -|Output voltage of the internal DC/DC converter, V|(% style="width:230px" %)12 ± 1
30 -|Output current of the internal DC/DC converter, A (maximum)|(% style="width:230px" %)3
31 -|Number of MOSFETs (to drive power contactors)|(% style="width:230px" %)4
32 -|MOSFETs output voltage, V (maximum)|(% style="width:230px" %)100
33 -|MOSFETs output current, A (maximum)|(% style="width:230px" %)5
34 -|Number of discrete inputs (dry contact)|(% style="width:230px" %)4
35 -|Number of discrete outputs|(% style="width:230px" %)4
36 -|Discrete outputs voltage, V (typical)|(% style="width:230px" %)5
37 -|Discrete outputs current, mA (maximum)|(% style="width:230px" %)100
27 +|Output voltage of the internal DC/DC converter, V|12 ± 1
28 +|Output current of the internal DC/DC converter, A (maximum)|3
29 +|Number of programmable MOSFETs for contactors (100V, 5A)|4
30 +|Number of programmable discrete inputs (dry contact)|4
31 +|Number of programmable discrete outputs (5V, total 100mA)|4
38 38  |Type of the current sensor|(% style="width:230px" %)Hall-Effect sensor, bidirectional, (LEM series: HASS, HTFS, DHAB)
39 39  |Wired interfaces|(% style="width:230px" %)1xCAN / 1xRS-485 / 1xUSB
40 -|Wireless interfaces|(% style="width:230px" %)Wi-Fi (optional)
41 41  |Dimensions (length × width × height), mm|(% style="width:230px" %)140 × 117 × 17
42 42  |Weight, g|(% style="width:230px" %)240 ± 5
43 43  |Operating temperature range, °С|(% style="width:230px" %)-40 to +85
37 +|Headers X1, X3-X9 type|Molex series Micro-Fit
44 44  
45 45  == Overall and mounting dimensions ==
46 46  
... ... @@ -52,13 +52,4 @@
52 52  
53 53  [[image:1733738121167-480.png]]
54 54  
55 -== Safety rules ==
56 -
57 -The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools, and appliances.
58 -
59 -(% class="box errormessage" %)
60 -(((
61 -**The system is not designed to work with batteries with total voltage more than 80 volts.**
62 -)))
63 -
64 64