Last modified by Admin on 2025/05/13 17:17

From version 16.1
edited by Admin
on 2025/05/12 10:10
Change comment: There is no comment for this version
To version 5.1
edited by Admin
on 2025/02/27 12:25
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -5,42 +5,41 @@
5 5  
6 6  == Specifications ==
7 7  
8 -(% style="width:642px" %)
9 -|(% style="width:402px" %)**Parameter**|(% style="width:237px" %)**Value**
10 -|(% style="width:402px" %)Battery voltage, V|(% style="width:237px" %)16 to 78
11 -|(% style="width:402px" %)(((
8 +(% style="width:624px" %)
9 +|**Parameter**|(% style="width:230px" %)**Value**
10 +|Battery voltage, V|(% style="width:230px" %)14 to 78
11 +|(((
12 12  Current consumption @48 V, mA (maximum):
13 + work (no load)
14 + standby
15 +)))|(% style="width:230px" %)(((
13 13  
14 -* work (no load)
15 -* standby
16 -)))|(% style="width:237px" %)(((
17 -
18 -
19 19  30
20 20  0.2
21 21  )))
22 -|(% style="width:402px" %)Number of cells|(% style="width:237px" %)6 to 18
23 -|(% style="width:402px" %)Cell balancing type|(% style="width:237px" %)Passive
24 -|(% style="width:402px" %)Cell balancing current, mA, @ 4.2 V|(% style="width:237px" %)220
25 -|(% style="width:402px" %)Cell voltage measurement error, V|(% style="width:237px" %)0.004
26 -|(% style="width:402px" %)Cell temperature measurement error, °С|(% style="width:237px" %)2
27 -|(% style="width:402px" %)Output voltage of the internal DC/DC converter, V|(% style="width:237px" %)12 ± 1
28 -|(% style="width:402px" %)Output current of the internal DC/DC converter, A (maximum)|(% style="width:237px" %)3
29 -|(% style="width:402px" %)Number of programmable MOSFETs for contactors (40V, 5A)|(% style="width:237px" %)4
30 -|(% style="width:402px" %)Number of programmable discrete inputs (dry contact)|(% style="width:237px" %)4
31 -|(% style="width:402px" %)Number of programmable discrete outputs (5V, total 200mA)|(% style="width:237px" %)4
32 -|(% style="width:402px" %)Type of the current sensor|(% style="width:237px" %)Hall-Effect sensor, bidirectional, (LEM series: HASS, HTFS, DHAB)
33 -|(% style="width:402px" %)Wired interfaces|(% style="width:237px" %)1xCAN / 1xRS-485 / 1xUSB
34 -|CAN output voltage, V|5.0 ± 0.5
35 -|CAN output current, mA (maximum)|400
36 -|(% style="width:402px" %)Dimensions (length × width × height), mm|(% style="width:237px" %)140 × 117 × 17
37 -|(% style="width:402px" %)Weight, g|(% style="width:237px" %)240 ± 20
38 -|(% style="width:402px" %)Operating temperature range, °С|(% style="width:237px" %)-40 to +85
39 -|(% style="width:402px" %)Headers X1, X3-X9 type|(% style="width:237px" %)Molex series Micro-Fit
20 +|Number of cells|(% style="width:230px" %)6 to 18
21 +|Cell balancing type|(% style="width:230px" %)Passive
22 +|Cell balancing current, mA, @ 4.2 V|(% style="width:230px" %)220
23 +|Cell voltage measurement error, V|(% style="width:230px" %)0.004
24 +|Cell temperature measurement error, °С|(% style="width:230px" %)2
25 +|Output voltage of the internal DC/DC converter, V|(% style="width:230px" %)12 ± 1
26 +|Output current of the internal DC/DC converter, A (maximum)|(% style="width:230px" %)3
27 +|Number of MOSFETs (to drive power contactors)|(% style="width:230px" %)4
28 +|MOSFETs output voltage, V (maximum)|(% style="width:230px" %)100
29 +|MOSFETs output current, A (maximum)|(% style="width:230px" %)5
30 +|Number of discrete inputs (dry contact)|(% style="width:230px" %)4
31 +|Number of discrete outputs|(% style="width:230px" %)4
32 +|Discrete outputs voltage, V (typical)|(% style="width:230px" %)5
33 +|Discrete outputs current, mA (maximum)|(% style="width:230px" %)100
34 +|Type of the current sensor|(% style="width:230px" %)Hall-Effect sensor, bidirectional, (LEM series: HASS, HTFS, DHAB)
35 +|Wired interfaces|(% style="width:230px" %)1xCAN / 1xRS-485 / 1xUSB
36 +|Dimensions (length × width × height), mm|(% style="width:230px" %)140 × 117 × 17
37 +|Weight, g|(% style="width:230px" %)240 ± 5
38 +|Operating temperature range, °С|(% style="width:230px" %)-40 to +85
40 40  
41 41  == Overall and mounting dimensions ==
42 42  
43 -[[image:1746624852753-514.png||data-xwiki-image-style-alignment="center" height="487" width="450"]]
42 +[[image:1733738049362-366.png||data-xwiki-image-style-alignment="center" height="471" width="418"]]
44 44  
45 45  == Typical battery system ==
46 46  
... ... @@ -48,4 +48,13 @@
48 48  
49 49  [[image:1733738121167-480.png]]
50 50  
50 +== Safety rules ==
51 +
52 +The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools, and appliances.
53 +
54 +(% class="box errormessage" %)
55 +(((
56 +**The system is not designed to work with batteries with total voltage more than 80 volts.**
57 +)))
58 +
51 51  
1746624836334-361.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -36.2 KB
Content
1746624852753-514.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -36.2 KB
Content