Last modified by Admin on 2025/05/13 17:17

From version 11.1
edited by Admin
on 2025/05/06 16:35
Change comment: There is no comment for this version
To version 10.1
edited by Admin
on 2025/05/06 16:34
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -5,36 +5,36 @@
5 5  
6 6  == Specifications ==
7 7  
8 -(% style="width:642px" %)
9 -|(% style="width:402px" %)**Parameter**|(% style="width:237px" %)**Value**
10 -|(% style="width:402px" %)Battery voltage, V|(% style="width:237px" %)14 to 78
11 -|(% style="width:402px" %)(((
8 +(% style="width:624px" %)
9 +|**Parameter**|(% style="width:230px" %)**Value**
10 +|Battery voltage, V|(% style="width:230px" %)14 to 78
11 +|(((
12 12  Current consumption @48 V, mA (maximum):
13 13  
14 14  * work (no load)
15 15  * standby
16 -)))|(% style="width:237px" %)(((
16 +)))|(% style="width:230px" %)(((
17 17  
18 18  
19 19  30
20 20  0.2
21 21  )))
22 -|(% style="width:402px" %)Number of cells|(% style="width:237px" %)6 to 18
23 -|(% style="width:402px" %)Cell balancing type|(% style="width:237px" %)Passive
24 -|(% style="width:402px" %)Cell balancing current, mA, @ 4.2 V|(% style="width:237px" %)220
25 -|(% style="width:402px" %)Cell voltage measurement error, V|(% style="width:237px" %)0.004
26 -|(% style="width:402px" %)Cell temperature measurement error, °С|(% style="width:237px" %)2
27 -|(% style="width:402px" %)Output voltage of the internal DC/DC converter, V|(% style="width:237px" %)12 ± 1
28 -|(% style="width:402px" %)Output current of the internal DC/DC converter, A (maximum)|(% style="width:237px" %)3
29 -|(% style="width:402px" %)Number of programmable MOSFETs for contactors (100V, 5A)|(% style="width:237px" %)4
30 -|(% style="width:402px" %)Number of programmable discrete inputs (dry contact)|(% style="width:237px" %)4
31 -|(% style="width:402px" %)Number of programmable discrete outputs (5V, total 100mA)|(% style="width:237px" %)4
32 -|(% style="width:402px" %)Type of the current sensor|(% style="width:237px" %)Hall-Effect sensor, bidirectional, (LEM series: HASS, HTFS, DHAB)
33 -|(% style="width:402px" %)Wired interfaces|(% style="width:237px" %)1xCAN / 1xRS-485 / 1xUSB
34 -|(% style="width:402px" %)Dimensions (length × width × height), mm|(% style="width:237px" %)140 × 117 × 17
35 -|(% style="width:402px" %)Weight, g|(% style="width:237px" %)240 ± 5
36 -|(% style="width:402px" %)Operating temperature range, °С|(% style="width:237px" %)-40 to +85
37 -|(% style="width:402px" %)Headers X1, X3-X9 type|(% style="width:237px" %)Molex series Micro-Fit
22 +|Number of cells|(% style="width:230px" %)6 to 18
23 +|Cell balancing type|(% style="width:230px" %)Passive
24 +|Cell balancing current, mA, @ 4.2 V|(% style="width:230px" %)220
25 +|Cell voltage measurement error, V|(% style="width:230px" %)0.004
26 +|Cell temperature measurement error, °С|(% style="width:230px" %)2
27 +|Output voltage of the internal DC/DC converter, V|12 ± 1
28 +|Output current of the internal DC/DC converter, A (maximum)|3
29 +|Number of programmable MOSFETs for contactors (100V, 5A)|4
30 +|Number of programmable discrete inputs (dry contact)|4
31 +|Number of programmable discrete outputs (5V, total 100mA)|4
32 +|Type of the current sensor|(% style="width:230px" %)Hall-Effect sensor, bidirectional, (LEM series: HASS, HTFS, DHAB)
33 +|Wired interfaces|(% style="width:230px" %)1xCAN / 1xRS-485 / 1xUSB
34 +|Dimensions (length × width × height), mm|(% style="width:230px" %)140 × 117 × 17
35 +|Weight, g|(% style="width:230px" %)240 ± 5
36 +|Operating temperature range, °С|(% style="width:230px" %)-40 to +85
37 +|Headers X1, X3-X9 type|Molex series Micro-Fit
38 38  
39 39  == Overall and mounting dimensions ==
40 40