24 24  |Cell balancing current, mA, @ 4.2 V|(% style="width:230px" %)220
25 25  |Cell voltage measurement error, V|(% style="width:230px" %)0.004
26 26  |Cell temperature measurement error, °С|(% style="width:230px" %)2
27 -|Output voltage of the internal DC/DC converter, V|12 ± 1
28 -|Output current of the internal DC/DC converter, A (maximum)|3
29 -|Number of programmable MOSFETs for contactors (100V, 5A)|4
30 -|Number of programmable discrete inputs (dry contact)|4
31 -|Number of programmable discrete outputs (5V, total 100mA)|4
27 +|Output voltage of the internal DC/DC converter, V|(% style="width:230px" %)12 ± 1
28 +|Output current of the internal DC/DC converter, A (maximum)|(% style="width:230px" %)3
29 +|Number of MOSFETs (to drive power contactors)|(% style="width:230px" %)4
30 +|MOSFETs output voltage, V (maximum)|(% style="width:230px" %)100
31 +|MOSFETs output current, A (maximum)|(% style="width:230px" %)5
32 +|Number of discrete inputs (dry contact)|(% style="width:230px" %)4
33 +|Number of discrete outputs|(% style="width:230px" %)4
34 +|Discrete outputs voltage, V (typical)|(% style="width:230px" %)5
35 +|Discrete outputs current, mA (maximum)|(% style="width:230px" %)100
32 32  |Type of the current sensor|(% style="width:230px" %)Hall-Effect sensor, bidirectional, (LEM series: HASS, HTFS, DHAB)
33 33  |Wired interfaces|(% style="width:230px" %)1xCAN / 1xRS-485 / 1xUSB
34 34  |Dimensions (length × width × height), mm|(% style="width:230px" %)140 × 117 × 17
... ... @@ -35,6 +35,7 @@
35 35  |Weight, g|(% style="width:230px" %)240 ± 5
36 36  |Operating temperature range, °С|(% style="width:230px" %)-40 to +85
37 37  |Headers X1, X3-X9 type|Molex series Micro-Fit
42 +| |(% style="width:230px" %)
38 38  
39 39  == Overall and mounting dimensions ==
40 40  
... ... @@ -46,4 +46,13 @@
46 46  
47 47  [[image:1733738121167-480.png]]
48 48  
54 +== Safety rules ==
55 +
56 +The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools, and appliances.
57 +
58 +(% class="box errormessage" %)
59 +(((
60 +**The system is not designed to work with batteries with total voltage more than 80 volts.**
61 +)))