Changes for page 1. Technical specifications
Last modified by Admin on 2025/05/13 17:17
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -24,11 +24,15 @@ 24 24 |Cell balancing current, mA, @ 4.2 V|(% style="width:230px" %)220 25 25 |Cell voltage measurement error, V|(% style="width:230px" %)0.004 26 26 |Cell temperature measurement error, °С|(% style="width:230px" %)2 27 -|Output voltage of the internal DC/DC converter, V|12 ± 1 28 -|Output current of the internal DC/DC converter, A (maximum)|3 29 -|Number of programmable MOSFETs for contactors (100V, 5A)|4 30 -|Number of programmable discrete inputs (dry contact)|4 31 -|Number of programmable discrete outputs (5V, total 100mA)|4 27 +|Output voltage of the internal DC/DC converter, V|(% style="width:230px" %)12 ± 1 28 +|Output current of the internal DC/DC converter, A (maximum)|(% style="width:230px" %)3 29 +|Number of MOSFETs (to drive power contactors)|(% style="width:230px" %)4 30 +|MOSFETs output voltage, V (maximum)|(% style="width:230px" %)100 31 +|MOSFETs output current, A (maximum)|(% style="width:230px" %)5 32 +|Number of discrete inputs (dry contact)|(% style="width:230px" %)4 33 +|Number of discrete outputs|(% style="width:230px" %)4 34 +|Discrete outputs voltage, V (typical)|(% style="width:230px" %)5 35 +|Discrete outputs current, mA (maximum)|(% style="width:230px" %)100 32 32 |Type of the current sensor|(% style="width:230px" %)Hall-Effect sensor, bidirectional, (LEM series: HASS, HTFS, DHAB) 33 33 |Wired interfaces|(% style="width:230px" %)1xCAN / 1xRS-485 / 1xUSB 34 34 |Dimensions (length × width × height), mm|(% style="width:230px" %)140 × 117 × 17 ... ... @@ -35,6 +35,7 @@ 35 35 |Weight, g|(% style="width:230px" %)240 ± 5 36 36 |Operating temperature range, °С|(% style="width:230px" %)-40 to +85 37 37 |Headers X1, X3-X9 type|Molex series Micro-Fit 42 +| |(% style="width:230px" %) 38 38 39 39 == Overall and mounting dimensions == 40 40 ... ... @@ -46,4 +46,13 @@ 46 46 47 47 [[image:1733738121167-480.png]] 48 48 54 +== Safety rules == 55 + 56 +The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools, and appliances. 57 + 58 +(% class="box errormessage" %) 59 +((( 60 +**The system is not designed to work with batteries with total voltage more than 80 volts.** 61 +))) 62 + 49 49