Changes for page 6.1 CANopen PDO protocol
Last modified by Admin on 2025/02/28 10:26
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -94,11 +94,11 @@ 94 94 95 95 bit 6 – “Discharging current present”; 96 96 97 -bit 7 – “ Voltagetoo high” (EV);97 +bit 7 – “Increased voltage” (EV); 98 98 99 -bit 8 – “Heat er”(0 – off, 1 – on);99 +bit 8 – “High DCH temperature”; 100 100 101 -bit 9 – “Cooler” (0 – off, 1 – on); 101 +bit 9 – “Cooler”, state of the cooler (0 – off, 1 – on); 102 102 103 103 bit 10 – “HYG shutdown”, command from the HYG forklift to open the discharging contactor; 104 104 ... ... @@ -110,11 +110,11 @@ 110 110 111 111 bit 14 – “Cell analysis”, signal of started analysis of the cells; 112 112 113 -bit 15 – reserved (setto 0);113 +bit 15 – “Balancing series 1”; 114 114 115 -bit 16 – reserved (setto 0);115 +bit 16 – “Balancing series 2”; 116 116 117 -bit 17 – “Discharging (AUX)” (0 – open, 1 – closed); 117 +bit 17 – “Discharging (AUX)” (0 – opened, 1 – closed); 118 118 119 119 bit 18 – “Acknowledgement of power down”; 120 120 ... ... @@ -132,9 +132,7 @@ 132 132 133 133 bit 25 – “Power up”; 134 134 135 -bit 26 – “External 1”; 136 - 137 -bits 27–31 – reserved. 135 +bits 26–31 – reserved. 138 138 )))|(% style="width:121px" %)U32|(% style="width:95px" %) 139 139 |**4–7**|(% style="width:332px" %)((( 140 140 Errors register 1 (bitfield): ... ... @@ -151,13 +151,13 @@ 151 151 152 152 bit 5 – “Battery cover”; 153 153 154 -bit 6 – reserved(setto 0);152 +bit 6 – “High humidity”; 155 155 156 -bit 7 – reserved (set to 0);154 +bit 7 – “Water”; 157 157 158 -bit 8 – reserved(setto0);156 +bit 8 – “High logic temperature”, some BMS Logic device is overheated; 159 159 160 -bit 9 – “ Cell monitoroffline”, connection withthecellmonitoris lost;158 +bit 9 – “Logic offline”, connection with some BMS Logic device is lost; 161 161 162 162 bit 10 – “Critical error”; 163 163 ... ... @@ -175,9 +175,9 @@ 175 175 176 176 bit 17 – “High contactor temperature”, the discharging contactor is overheated; 177 177 178 -bit 18 – re served(setto0);176 +bit 18 – “Logic count error”, number of BMS Logic devices is incorrect; 179 179 180 -bit 19 – “ADC error”, battery current cannot be measured by theADC;178 +bit 19 – “ADC error”, battery current cannot be measured by ADC; 181 181 182 182 bit 20 – “Current sensor error”, wires which connect the current sensor with the BMS are damaged; 183 183 ... ... @@ -189,7 +189,7 @@ 189 189 190 190 bit 24 – “Shunt error”, internal error of the BMS Current sensor; 191 191 192 -bit 25 – reserved(seto0);190 +bit 25 – “Settings error”, checksum of the setting is incorrect; 193 193 194 194 bit 26 – “WDT reset”, device is reset by the watchdog timer; 195 195