5 == External equipment ==
6
7 Information about the status of external equipment is in the "External equipment" section.
8
9 === J1939 Charger ===
10
11 Information about the status of communication with a J1939 charger is available in the "External equipment → Chargers → J1939 charger" section:
12
13 [[image:1733755859045-332.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="89" width="800"]]
14
15 In this section:
16
17 * Online – a flag indicating if connection with the charger established;
18 * Voltage – a value of voltage received from the charger, V;
19 * Current – a value of current received from the charger, А.
20
21 === Eltek charger ===
22
23 Information about the status of communication with an Eltek charger is available in the "External equipment → Chargers → Eltek charger" section:
24
25 [[image:1733755859047-203.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="165" width="800"]]
26
27 In this section:
28
29 * Status:
30 ** Offline – no connection with charger;
31 ** No charge;
32 ** Charge;
33 ** Recoverable error;
34 ** Non-recoverable error;
35 * Input voltage, V;
36 * Input current, А;
37 * Input frequency, Hz;
38 * Output voltage, V;
39 * Output current, А;
40 * Primary temperature – temperature measured by the main temperature sensor, °C;
41 * Secondary temperature – temperature measured by an additional temperature sensor, °C;
42 * Max power – maximum power that the charger can provide, W;
43 * Available power, %;
44 * Errors – hexadecimal word with charger errors.
45
46 === MicroPower charger ===
47
48 Information about the status of communication with a MicroPower charger is available in the "External equipment → Chargers → MicroPower charger" section:
49
50 [[image:1733755859049-468.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="141" width="800"]]
51
52 In this section:
53
54 * Online – a flag of normal communication with the charger;
55 * Voltage, V;
56 * Current, A;
57 * Power, W;
58 * Charge information:
59 ** Voltage reached – output voltage of the charger is close to the required value;
60 ** Current reached – output current of the charger is close to the required value;
61 ** Power reached – output power of the charger is close to the required value;
62 * Limiter mode:
63 ** None;
64 ** Voltage;
65 ** Current;
66 ** Power;
67 ** Int. temperature – output is limited due to internal charger temperature;
68 ** Volt. boundary – bound voltage is reached;
69 ** Curr. boundary – bound current is reached;
70 ** Pow. boundary – bound power is reached;
71 ** DC limit;
72 ** AC limit;
73 ** Pow. AC limit – input power limitation;
74 ** Phase error;
75 * Cause of derate:
76 ** Phase error;
77 ** Parameters;
78 ** Poor power;
79 ** Internal temperature;
80 ** No load;
81 * Warnings, Errors:
82 ** Phase error;
83 ** Regulator error;
84 ** Low temperature;
85 ** High temperature;
86 ** Temperature protection;
87 ** CAN timeout.
88
89 === S.P.E. charger ===
90
91 Information about the status of communication with an S.P.E. charger is available in the "External equipment → Chargers → S.P.E. charger" section:
92
93 [[image:1733755859050-601.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="80" width="800"]]
94
95 In this section:
96
97 * Online – a flag of normal communication with the charger;
98 * Voltage, V;
99 * Current, A.
100
101 === Bassi charger ===
102
103 Information about the status of communication with a Bassi charger is available in the "External equipment → Chargers → Bassi charger" section:
104
105 [[image:1733755859051-465.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="110" width="800"]]
106
107 In this section:
108
109 * Online – a flag of normal communication with the charger;
110 * Voltage – voltage measured by the charger, V;
111 * Current – current measured by the charger, A;
112 * Internal temperature – temperature of the charger, °C;
113 * Charge – energy which the charger transferred to the battery, Ah;
114 * Charging time – duration of the battery charging, minute.
115
116 === ATIB charger ===
117
118 Information about the status of communication with an ATIB charger is available in the "External equipment → Chargers → ATIB charger" section:
119
120 [[image:1733755859051-754.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="90" width="800"]]
121
122 In this section:
123
124 * Online – a flag of normal communication with the charger;
125 * Voltage – voltage measured by the charger, V;
126 * Current – current measured by the charger, A;
127 * Status – bitfield with status indicators:
128 ** Charger error;
129 ** High temperature;
130 ** Parameters out of limits;
131 ** Battery is not connected;
132 ** Communication error;
133 ** Thermal derating;
134 ** Precharge.
135
136 === Fronius charger ===
137
138 Information about the status of communication with a Fronius charger is available in the "External equipment → Chargers → Fronius charger" section:
139
140 [[image:1733755859052-849.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="87" width="800"]]
141
142 In this section:
143
144 * Online – a flag of normal communication with the charger;
145 * Voltage – voltage measured by the charger, V;
146 * Current – current measured by the charger, A;
147 * Status – bitfield with status indicators:
148 ** Power unit on – charger power status;
149 ** Voltage match finish – charging finished due to voltage achievement;
150 ** Delay;
151 ** Derating;
152 ** Error – charger error;
153 ** Break – charging stopped.
154
155 === Webasto charger ===
156
157 Information about the status of communication with a Webasto charger is available in the "External equipment → Chargers → Webasto charger" section:
158
159 [[image:1733755859053-353.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="100" width="800"]]
160
161 In this section:
162
163 * Online – a flag of normal communication with the charger;
164 * Voltage – voltage measured by the charger, V;
165 * Available current – maximum allowable charging current, A;
166 * Actual current – current measured by the charger, A;
167 * Status – bitfield with status indicators:
168 ** Ready to charge;
169 ** Charging – battery is charging;
170 ** High temperature – charger is overheated;
171 ** Fault state – charger error.
172
173 === Skytronic charger ===
174
175 Information about the status of communication with a Skytronic charger is available in the "External equipment → Chargers → Skytronic charger" section:
176
177 [[image:1733755874627-493.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="78" width="800"]]
178
179 In this section:
180
181 * Online – a flag of normal communication with the charger;
182 * Voltage – voltage measured by the charger, V;
183 * Actual current – current measured by the charger, A.
184
185 === Sunny Island inverter ===
186
187 Information about the status of communication with a SMA Sunny Island inverter is available in the "External equipment → Inverters → Sunny Island inverter " section:
188
189 [[image:1733755874628-796.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="68" width="800"]]
190
191 In this section:
192
193 * Voltage, V.
194
195 === HYG Class I-III truck ===
196
197 Information about the status of communication with a HYG Class I-III truck is available in the "External equipment → Trucks and Vehicles → HYG Class I-III truck" section:
198
199 [[image:1733755874629-863.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="109" width="800"]]
200
201 In this section:
202
203 * Online – a flag of normal communication with the forklift;
204 * Voltage, V;
205 * Current, А;
206 * Temperature, °C;
207 * Thermal derate, %;
208 * Control – bitfield with control commands transferred to the forklift:
209 ** Inhibit operation;
210 ** Immediate shutdown;
211 ** Limited operation – mode of limited functionality (it is formed if the battery SOC is less than the “SOC: Limited operation” value);
212 ** Traction inhibit (Gen.2: charger connected);
213 ** Lift lockout – blocking of the lift (it is formed if the battery SOC is less than the “SOC: Lift lockout” value).
214
215 === Combilift truck ===
216
217 Information about the status of communication with a Combilift truck is available in the "External equipment → Trucks and Vehicles → Combilift truck" section:
218
219 [[image:1733755874630-783.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="109" width="800"]]
220
221 In this section:
222
223 * Online – a flag of normal communication with equipment;
224 * Voltage, V;
225 * Current, А;
226 * Temperature, °C;
227 * Control – bitfield with control commands transferred to the forklift:
228 ** Power shutdown – turn off the forklift power;
229 ** Traction inhibit;
230 ** Lift lockout – blocking of the lift (it is formed if the battery SOC is less than the “SOC: Lift lockout” value);
231 ** Limited operation – mode of limited functionality (it is formed if the battery SOC is less than the “SOC: Limited operation” value).
232
233 === Spirit AGV ===
234
235 Information about the status of communication with a Spirit AGV is available in the "External equipment → Trucks and Vehicles → Spirit AGV" section:
236
237 [[image:1733755874631-567.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="132" width="800"]]
238
239 In this section:
240
241 * Online – a flag of normal communication with the truck;
242 * Voltage, V;
243 * Current, A;
244 * Temperature, °C;
245 * Control 1 – first bitfield with control commands transferred to the forklift:
246 ** Inhibit operation;
247 ** Immediate shutdown;
248 ** Limited operation – mode of limited functionality (it is formed if the battery SOC is less than the “SOC: Limited operation” value);
249 ** Traction inhibit;
250 ** Lift lockout – blocking of the lift (it is formed if the battery SOC is less than the “SOC: Lift lockout” value).
251 * Control 2 – second bitfield with control commands transferred to the forklift:
252 ** Charger connected;
253 ** No charging or discharging current;
254 ** Charging;
255 ** Discharging;
256 ** Cell monitor offline / Cell count error / Battery cover opened;
257 ** Overcurrent / Overvoltage / Undervoltage;
258 ** High temperature / Low temperature;
259 ** Board high temperature.
260 * Status – forklift status sent to BMS:
261 ** Shutdown immediately;
262 ** Confirmed shutdown;
263 ** Charging / not charging;
264 ** Charger critical error;
265 ** Charger non-critical error;
266 * Waiting time, s.
267
268 === Crown truck ===
269
270 Information about the status of communication with a Crown truck is available in the "External equipment → Trucks and Vehicles → Crown truck" section:
271
272 [[image:1733755874633-855.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="87" width="800"]]
273
274 In this section:
275
276 * Online – communication status with the BMS Crown adapter;
277 * Voltage A2 (from battery) – voltage measured by the BMS Crown on battery, V;
278 * Voltage A1 (from truck) – voltage produced by the Crown forklift system, V;
279 * Relay – command to power on the Crown forklift.
280
281 === ZiK truck ===
282
283 Information about the status of communication with a ZiK truck is available in the "External equipment → Trucks and Vehicles → ZiK truck" section:
284
285 [[image:1733755874634-378.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="165" width="800"]]
286
287 In this section:
288
289 * Battery voltage, V;
290 * Battery current, A;
291 * Supercapacitor voltage, V;
292 * Supercapacitor temperature, °C;
293 * Control – bitfield with control commands transferred to the forklift:
294 ** Discharging;
295 ** Allow discharging;
296 ** Charge supercapacitor;
297 ** Recuperation resistor;
298 ** Inhibit operation;
299 ** Undervoltage;
300 ** Overcurrent;
301 ** Limited operation;
302
303 === Basic J1939 vehicle ===
304
305 Information about the status of communication with a vehicle via the J1939 protocol is available in the "External equipment → Trucks and Vehicles → Basic J1939 vehicle" section:
306
307 [[image:1733755874635-441.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="67" width="800"]]
308
309 In this section:
310
311 * Online – a flag of normal communication with the vehicle;
312 * Maximum DOD – maximum allowed DOD of the battery, %.
313
314 === Main X ===
315
316 Information about the status of communication with the BMS Main X is available in the "External equipment → BMS → Main X" section:
317
318 [[image:1733755874636-249.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="67" width="800"]]
319
320 In this section:
321
322 * Online – connection status.