190 190  
191 191  In this section:
192 192  
193 -* Voltage, V.
194 -* Current, A;
195 -* Tempareture, °C;
196 -* SOC, %;
197 -* SOH, %;
198 -* Mode – inverter working mode code;
199 -* State – inverter state code;
200 -* Error – inverter error code;
201 -* Charging voltage, V.
193 +* Enable – a flag to enable communication with the inverter;
194 +* CAN port – port which is used to communicate with the inverter:
195 +** CAN1 (ext);
196 +** CAN2 (int);
197 +* Receive timeout – a timeout for receiving packets from the inverter (if no data is being received from the inverter during this time, the connection loss flag is set), millisecond;
198 +* Output period – a period of sending commands to the inverter, millisecond;
199 +* Charge voltage, V – maximum charging voltage, V;
200 +* Charge current, А – maximum charging current, A;
201 +* Discharge voltage (min) – minimum discharging voltage, V;
202 +* Discharge current – maximum discharging current, А;
203 +* Invert current – a flag to inverse current sent to the inverter;
202 202  
205 +When working with the Sunny Island inverter, the BMS Main 3 device sends messages with the values of voltage and charge/discharge current continuously with the period “Output period”: Charging voltage, Charging current, Discharging voltage, Discharging current.
206 +
203 203  === Pylontech inverter ===
204 204  
205 -Information about the status of communication with a Pylontech inverter is available in the "External equipment → Inverters → Pylontech inverter" section:
209 +To change the parameters of communication with a Pylontech inverter, select the "External equipment → Inverters and loads → Pylontech inverter" section:
206 206  
207 207  [[image:1740651353463-581.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="83" width="800"]]
208 208  
... ... @@ -210,25 +210,6 @@
210 210  
211 211  * Online – a flag of normal communication with the inverter;
212 212  
213 -=== ASTOM load bank (cycling) ===
214 -
215 -Information about the status of communication with a ASTOM load bank is available in the "External equipment → Inverters → ASTOM load bank (cycling)" section:
216 -
217 -[[image:1740651484968-315.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="168" width="800"]]
218 -
219 -In this section:
220 -
221 -* Current state – current state of the cycle algorithm;
222 -* Time elapsed, second;
223 -* Number of completed cycles;
224 -* Load bank online;
225 -* Load current, A;
226 -* Input voltage, V;
227 -* Maximim DOD – maximum measured DOD during cycling, Ah;
228 -* Logic index – BMS Logic identifier with fastest discharging cell connected;
229 -* Cell index – number of fastest discharging cell;
230 -* Start cycling – a trigger to start cycling.
231 -
232 232  === HYG Class I-III truck ===
233 233  
234 234  Information about the status of communication with a HYG Class I-III truck is available in the "External equipment → Trucks and Vehicles → HYG Class I-III truck" section:
... ... @@ -348,12 +348,6 @@
348 348  * Online – a flag of normal communication with the vehicle;
349 349  * Maximum DOD – maximum allowed DOD of the battery, %.
350 350  
351 -=== Bender iso165C ===
352 -
353 -Information about the status of communication with Bender iso165C is available in the "External equipment → IMD → Bender iso165C" section:
354 -
355 -[[image:Battery management systems.BMS Main 3.4\. Monitoring.4\.5 External equipment.WebHome@1733403652591-578.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="800"]]
356 -
357 357  === Main X ===
358 358  
359 359  Information about the status of communication with the BMS Main X is available in the "External equipment → BMS → Main X" section:
1740651749669-327.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -14.3 KB
Content
1740651767817-940.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -19.9 KB
Content