Changes for page 4.5 External equipment
Last modified by Admin on 2025/02/27 10:23
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -186,49 +186,12 @@ 186 186 187 187 Information about the status of communication with a SMA Sunny Island inverter is available in the "External equipment → Inverters → Sunny Island inverter " section: 188 188 189 -[[image:17 40651146561-123.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="159" width="800"]]189 +[[image:1733755874628-796.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="68" width="800"]] 190 190 191 191 In this section: 192 192 193 193 * Voltage, V. 194 -* Current, A; 195 -* Tempareture, °C; 196 -* SOC, %; 197 -* SOH, %; 198 -* Mode – inverter working mode code; 199 -* State – inverter state code; 200 -* Error – inverter error code; 201 -* Charging voltage, V. 202 202 203 -=== Pylontech inverter === 204 - 205 -Information about the status of communication with a Pylontech inverter is available in the "External equipment → Inverters → Pylontech inverter" section: 206 - 207 -[[image:1740651353463-581.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="83" width="800"]] 208 - 209 -In this section: 210 - 211 -* Online – a flag of normal communication with the inverter; 212 - 213 -=== ASTOM load bank (cycling) === 214 - 215 -Information about the status of communication with a ASTOM load bank is available in the "External equipment → Inverters → ASTOM load bank (cycling)" section: 216 - 217 -[[image:1740651484968-315.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="168" width="800"]] 218 - 219 -In this section: 220 - 221 -* Current state – current state of the cycle algorithm; 222 -* Time elapsed, second; 223 -* Number of completed cycles; 224 -* Load bank online; 225 -* Load current, A; 226 -* Input voltage, V; 227 -* Maximim DOD – maximum measured DOD during cycling, Ah; 228 -* Logic index – BMS Logic identifier with fastest discharging cell connected; 229 -* Cell index – number of fastest discharging cell; 230 -* Start cycling – a trigger to start cycling. 231 - 232 232 === HYG Class I-III truck === 233 233 234 234 Information about the status of communication with a HYG Class I-III truck is available in the "External equipment → Trucks and Vehicles → HYG Class I-III truck" section: ... ... @@ -348,12 +348,6 @@ 348 348 * Online – a flag of normal communication with the vehicle; 349 349 * Maximum DOD – maximum allowed DOD of the battery, %. 350 350 351 -=== Bender iso165C === 352 - 353 -Information about the status of communication with Bender iso165C is available in the "External equipment → IMD → Bender iso165C" section: 354 - 355 -[[image:Battery management systems.BMS Main 3.4\. Monitoring.4\.5 External equipment.WebHome@1733403652591-578.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="800"]] 356 - 357 357 === Main X === 358 358 359 359 Information about the status of communication with the BMS Main X is available in the "External equipment → BMS → Main X" section:
- 1740651353463-581.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -11.1 KB - Content
- 1740651484968-315.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -25.8 KB - Content