Changes for page 4.5 External equipment
Last modified by Admin on 2025/02/27 10:23
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -190,23 +190,19 @@ 190 190 191 191 In this section: 192 192 193 -* Enable – a flag to enable communication with the inverter; 194 -* CAN port – port which is used to communicate with the inverter: 195 -** CAN1 (ext); 196 -** CAN2 (int); 197 -* Receive timeout – a timeout for receiving packets from the inverter (if no data is being received from the inverter during this time, the connection loss flag is set), millisecond; 198 -* Output period – a period of sending commands to the inverter, millisecond; 199 -* Charge voltage, V – maximum charging voltage, V; 200 -* Charge current, А – maximum charging current, A; 201 -* Discharge voltage (min) – minimum discharging voltage, V; 202 -* Discharge current – maximum discharging current, А; 203 -* Invert current – a flag to inverse current sent to the inverter; 193 +* Voltage, V. 194 +* Current, A; 195 +* Tempareture, °C; 196 +* SOC, %; 197 +* SOH, %; 198 +* Mode – inverter working mode code; 199 +* State – inverter state code; 200 +* Error – inverter error code; 201 +* Charging voltage, V. 204 204 205 -When working with the Sunny Island inverter, the BMS Main 3 device sends messages with the values of voltage and charge/discharge current continuously with the period “Output period”: Charging voltage, Charging current, Discharging voltage, Discharging current. 206 - 207 207 === Pylontech inverter === 208 208 209 - Tochangetheparameters of communication with a Pylontech inverter,selectthe "External equipment → Invertersand loads→ Pylontech inverter" section:205 +Information about the status of communication with a Pylontech inverter is available in the "External equipment → Inverters → Pylontech inverter" section: 210 210 211 211 [[image:1740651353463-581.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="83" width="800"]] 212 212 ... ... @@ -214,6 +214,25 @@ 214 214 215 215 * Online – a flag of normal communication with the inverter; 216 216 213 +=== ASTOM load bank (cycling) === 214 + 215 +Information about the status of communication with a ASTOM load bank is available in the "External equipment → Inverters → ASTOM load bank (cycling)" section: 216 + 217 +[[image:1740651484968-315.png]] 218 + 219 +In this section: 220 + 221 +* Current state – current state of the cycle algorithm; 222 +* Time elapsed, second; 223 +* Number of completed cycles; 224 +* Load bank online; 225 +* Load current, A; 226 +* Input voltage, V; 227 +* Maximim DOD – maximum measured DOD during cycling, Ah; 228 +* Logic index – BMS Logic identifier with fastest discharging cell connected; 229 +* Cell index – number of fastest discharging cell; 230 +* Start cycling – a trigger to start cycling. 231 + 217 217 === HYG Class I-III truck === 218 218 219 219 Information about the status of communication with a HYG Class I-III truck is available in the "External equipment → Trucks and Vehicles → HYG Class I-III truck" section:
- 1740651484968-315.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +25.8 KB - Content