... ... @@ -190,25 +190,45 @@
190 190  
191 191  In this section:
192 192  
193 -* Enable – a flag to enable communication with the inverter;
194 -* CAN port – port which is used to communicate with the inverter:
195 -** CAN1 (ext);
196 -** CAN2 (int);
197 -* Receive timeout – a timeout for receiving packets from the inverter (if no data is being received from the inverter during this time, the connection loss flag is set), millisecond;
198 -* Output period – a period of sending commands to the inverter, millisecond;
199 -* Charge voltage, V – maximum charging voltage, V;
200 -* Charge current, А – maximum charging current, A;
201 -* Discharge voltage (min) – minimum discharging voltage, V;
202 -* Discharge current – maximum discharging current, А;
203 -* Invert current – a flag to inverse current sent to the inverter;
193 +* Voltage, V.
194 +* Current, A;
195 +* Tempareture, °C;
196 +* SOC, %;
197 +* SOH, %;
198 +* Mode – inverter working mode code;
199 +* State – inverter state code;
200 +* Error – inverter error code;
201 +* Charging voltage, V.
204 204  
205 -When working with the Sunny Island inverter, the BMS Main 3 device sends messages with the values of voltage and charge/discharge current continuously with the period “Output period”: Charging voltage, Charging current, Discharging voltage, Discharging current.
206 -
207 207  === Pylontech inverter ===
208 208  
209 -To change the parameters of communication with a Pylontech inverter, select the "External equipment → Inverters and loads → Pylontech inverter" section:
205 +Information about the status of communication with a Pylontech inverter is available in the "External equipment → Inverters → Pylontech inverter" section:
210 210  
207 +[[image:1740651353463-581.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="83" width="800"]]
211 211  
209 +In this section:
210 +
211 +* Online – a flag of normal communication with the inverter;
212 +
213 +=== ASTOM load bank (cycling) ===
214 +
215 +Information about the status of communication with a ASTOM load bank is available in the "External equipment → Inverters → ASTOM load bank (cycling)" section:
216 +
217 +[[image:1740651484968-315.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="168" width="800"]]
218 +
219 +In this section:
220 +
221 +* Current state – current state of the cycle algorithm;
222 +* Time elapsed, second;
223 +* Number of completed cycles;
224 +* Load bank online;
225 +* Load current, A;
226 +* Input voltage, V;
227 +* Maximim DOD – maximum measured DOD during cycling, Ah;
228 +* Logic index – BMS Logic identifier with fastest discharging cell connected;
229 +* Cell index – number of fastest discharging cell;
230 +* Start cycling – a trigger to start cycling.
231 +
212 212  === HYG Class I-III truck ===
213 213  
214 214  Information about the status of communication with a HYG Class I-III truck is available in the "External equipment → Trucks and Vehicles → HYG Class I-III truck" section:
... ... @@ -328,6 +328,12 @@
328 328  * Online – a flag of normal communication with the vehicle;
329 329  * Maximum DOD – maximum allowed DOD of the battery, %.
330 330  
351 +=== Bender iso165C ===
352 +
353 +Information about the status of communication with Bender iso165C is available in the "External equipment → IMD → Bender iso165C" section:
354 +
355 +[[image:Battery management systems.BMS Main 3.4\. Monitoring.4\.5 External equipment.WebHome@1733403652591-578.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="800"]]
356 +
331 331  === Main X ===
332 332  
333 333  Information about the status of communication with the BMS Main X is available in the "External equipment → BMS → Main X" section:
1740651484968-315.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +25.8 KB
Content
1740651749669-327.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +14.3 KB
Content
1740651767817-940.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +19.9 KB
Content