Changes for page 4.5 External equipment
Last modified by Admin on 2025/02/27 10:23
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -186,29 +186,12 @@ 186 186 187 187 Information about the status of communication with a SMA Sunny Island inverter is available in the "External equipment → Inverters → Sunny Island inverter " section: 188 188 189 -[[image:17 40651146561-123.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="159" width="800"]]189 +[[image:1733755874628-796.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="68" width="800"]] 190 190 191 191 In this section: 192 192 193 -* Enable – a flag to enable communication with the inverter; 194 -* CAN port – port which is used to communicate with the inverter: 195 -** CAN1 (ext); 196 -** CAN2 (int); 197 -* Receive timeout – a timeout for receiving packets from the inverter (if no data is being received from the inverter during this time, the connection loss flag is set), millisecond; 198 -* Output period – a period of sending commands to the inverter, millisecond; 199 -* Charge voltage, V – maximum charging voltage, V; 200 -* Charge current, А – maximum charging current, A; 201 -* Discharge voltage (min) – minimum discharging voltage, V; 202 -* Discharge current – maximum discharging current, А; 203 -* Invert current – a flag to inverse current sent to the inverter; 193 +* Voltage, V. 204 204 205 -When working with the Sunny Island inverter, the BMS Main 3 device sends messages with the values of voltage and charge/discharge current continuously with the period “Output period”: Charging voltage, Charging current, Discharging voltage, Discharging current. 206 - 207 -=== Pylontech inverter === 208 - 209 -To change the parameters of communication with a Pylontech inverter, select the "External equipment → Inverters and loads → Pylontech inverter" section: 210 - 211 - 212 212 === HYG Class I-III truck === 213 213 214 214 Information about the status of communication with a HYG Class I-III truck is available in the "External equipment → Trucks and Vehicles → HYG Class I-III truck" section:
- 1740651146561-123.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -22.5 KB - Content
- 1740651353463-581.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -11.1 KB - Content