... ... @@ -190,8 +190,25 @@
190 190  
191 191  In this section:
192 192  
193 -* Voltage, V.
193 +* Enable – a flag to enable communication with the inverter;
194 +* CAN port – port which is used to communicate with the inverter:
195 +** CAN1 (ext);
196 +** CAN2 (int);
197 +* Receive timeout – a timeout for receiving packets from the inverter (if no data is being received from the inverter during this time, the connection loss flag is set), millisecond;
198 +* Output period – a period of sending commands to the inverter, millisecond;
199 +* Charge voltage, V – maximum charging voltage, V;
200 +* Charge current, А – maximum charging current, A;
201 +* Discharge voltage (min) – minimum discharging voltage, V;
202 +* Discharge current – maximum discharging current, А;
203 +* Invert current – a flag to inverse current sent to the inverter;
194 194  
205 +When working with the Sunny Island inverter, the BMS Main 3 device sends messages with the values of voltage and charge/discharge current continuously with the period “Output period”: Charging voltage, Charging current, Discharging voltage, Discharging current.
206 +
207 +=== Pylontech inverter ===
208 +
209 +To change the parameters of communication with a Pylontech inverter, select the "External equipment → Inverters and loads → Pylontech inverter" section:
210 +
211 +
195 195  === HYG Class I-III truck ===
196 196  
197 197  Information about the status of communication with a HYG Class I-III truck is available in the "External equipment → Trucks and Vehicles → HYG Class I-III truck" section:
1740651353463-581.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +11.1 KB
Content