Summary

Details

Page properties
Content
... ... @@ -186,12 +186,49 @@
186 186  
187 187  Information about the status of communication with a SMA Sunny Island inverter is available in the "External equipment → Inverters → Sunny Island inverter " section:
188 188  
189 -[[image:1733755874628-796.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="68" width="800"]]
189 +[[image:1740651146561-123.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="159" width="800"]]
190 190  
191 191  In this section:
192 192  
193 193  * Voltage, V.
194 +* Current, A;
195 +* Tempareture, °C;
196 +* SOC, %;
197 +* SOH, %;
198 +* Mode – inverter working mode code;
199 +* State – inverter state code;
200 +* Error – inverter error code;
201 +* Charging voltage, V.
194 194  
203 +=== Pylontech inverter ===
204 +
205 +Information about the status of communication with a Pylontech inverter is available in the "External equipment → Inverters → Pylontech inverter" section:
206 +
207 +[[image:1740651353463-581.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="83" width="800"]]
208 +
209 +In this section:
210 +
211 +* Online – a flag of normal communication with the inverter;
212 +
213 +=== ASTOM load bank (cycling) ===
214 +
215 +Information about the status of communication with a ASTOM load bank is available in the "External equipment → Inverters → ASTOM load bank (cycling)" section:
216 +
217 +[[image:1740651484968-315.png]]
218 +
219 +In this section:
220 +
221 +* Current state – current state of the cycle algorithm;
222 +* Time elapsed, second;
223 +* Number of completed cycles;
224 +* Load bank online;
225 +* Load current, A;
226 +* Input voltage, V;
227 +* Maximim DOD – maximum measured DOD during cycling, Ah;
228 +* Logic index – BMS Logic identifier with fastest discharging cell connected;
229 +* Cell index – number of fastest discharging cell;
230 +* Start cycling – a trigger to start cycling.
231 +
195 195  === HYG Class I-III truck ===
196 196  
197 197  Information about the status of communication with a HYG Class I-III truck is available in the "External equipment → Trucks and Vehicles → HYG Class I-III truck" section:
1740651146561-123.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +22.5 KB
Content
1740651353463-581.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +11.1 KB
Content
1740651484968-315.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +25.8 KB
Content