Changes for page 4.5 External equipment
Last modified by Admin on 2025/02/27 10:23
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 6 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -186,12 +186,49 @@ 186 186 187 187 Information about the status of communication with a SMA Sunny Island inverter is available in the "External equipment → Inverters → Sunny Island inverter " section: 188 188 189 -[[image:17 33755874628-796.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="68" width="800"]]189 +[[image:1740651146561-123.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="159" width="800"]] 190 190 191 191 In this section: 192 192 193 193 * Voltage, V. 194 +* Current, A; 195 +* Tempareture, °C; 196 +* SOC, %; 197 +* SOH, %; 198 +* Mode – inverter working mode code; 199 +* State – inverter state code; 200 +* Error – inverter error code; 201 +* Charging voltage, V. 194 194 203 +=== Pylontech inverter === 204 + 205 +Information about the status of communication with a Pylontech inverter is available in the "External equipment → Inverters → Pylontech inverter" section: 206 + 207 +[[image:1740651353463-581.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="83" width="800"]] 208 + 209 +In this section: 210 + 211 +* Online – a flag of normal communication with the inverter; 212 + 213 +=== ASTOM load bank (cycling) === 214 + 215 +Information about the status of communication with a ASTOM load bank is available in the "External equipment → Inverters → ASTOM load bank (cycling)" section: 216 + 217 +[[image:1740651484968-315.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="168" width="800"]] 218 + 219 +In this section: 220 + 221 +* Current state – current state of the cycle algorithm; 222 +* Time elapsed, second; 223 +* Number of completed cycles; 224 +* Load bank online; 225 +* Load current, A; 226 +* Input voltage, V; 227 +* Maximim DOD – maximum measured DOD during cycling, Ah; 228 +* Logic index – BMS Logic identifier with fastest discharging cell connected; 229 +* Cell index – number of fastest discharging cell; 230 +* Start cycling – a trigger to start cycling. 231 + 195 195 === HYG Class I-III truck === 196 196 197 197 Information about the status of communication with a HYG Class I-III truck is available in the "External equipment → Trucks and Vehicles → HYG Class I-III truck" section: ... ... @@ -311,11 +311,41 @@ 311 311 * Online – a flag of normal communication with the vehicle; 312 312 * Maximum DOD – maximum allowed DOD of the battery, %. 313 313 351 +=== Bender iso165C === 352 + 353 +Information about the status of communication with Bender iso165C is available in the "External equipment → IMD → Bender iso165C" section: 354 + 355 +[[image:1740651749669-327.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="98" width="800"]] 356 + 357 + 358 +In this section: 359 + 360 +* Online – a flag of normal communication with the IMD; 361 +* Configured – a flag indicating successful device set up; 362 +* Status – device status; 363 +* Insulation resistance – measured insulation resistance, Ohm. 364 + 365 +=== BMS IMD === 366 + 367 +Information about the status of communication with BMS IMD is available in the "External equipment → IMD → BMS IMD" section: 368 + 369 +[[image:1740651767817-940.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="135" width="800"]] 370 + 371 +In this section: 372 + 373 +* Online – a flag of normal communication with the IMD; 374 +* Configured – a flag indicating successful device set up; 375 +* Insulation status; 376 +* Internal errors – internal device errors; 377 +* Device state – device status; 378 +* Insulation resistance (plus) – measured insulation resistance between positive line and chassis, Ohm; 379 +* Insulation resistance (minus) – measured insulation resistance between negative line and chassis, Ohm. 380 + 314 314 === Main X === 315 315 316 316 Information about the status of communication with the BMS Main X is available in the "External equipment → BMS → Main X" section: 317 317 318 -[[image:17 33755874636-249.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="67" width="800"]]385 +[[image:1740651814966-731.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="86" width="800"]] 319 319 320 320 In this section: 321 321
- 1740651146561-123.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.5 KB - Content
- 1740651353463-581.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +11.1 KB - Content
- 1740651484968-315.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +25.8 KB - Content
- 1740651749669-327.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +14.3 KB - Content
- 1740651767817-940.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.9 KB - Content
- 1740651814966-731.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +10.7 KB - Content