Changes for page 4.5 External equipment
Last modified by Admin on 2025/02/27 10:23
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - drafts.BMS Mini S.4\. Monitoring.WebHome1 +Battery management systems.BMS Mini S.4\. Monitoring.WebHome - Content
-
... ... @@ -186,12 +186,49 @@ 186 186 187 187 Information about the status of communication with a SMA Sunny Island inverter is available in the "External equipment → Inverters → Sunny Island inverter " section: 188 188 189 -[[image:17 33755874628-796.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="68" width="800"]]189 +[[image:1740651146561-123.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="159" width="800"]] 190 190 191 191 In this section: 192 192 193 193 * Voltage, V. 194 +* Current, A; 195 +* Tempareture, °C; 196 +* SOC, %; 197 +* SOH, %; 198 +* Mode – inverter working mode code; 199 +* State – inverter state code; 200 +* Error – inverter error code; 201 +* Charging voltage, V. 194 194 203 +=== Pylontech inverter === 204 + 205 +Information about the status of communication with a Pylontech inverter is available in the "External equipment → Inverters → Pylontech inverter" section: 206 + 207 +[[image:1740651353463-581.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="83" width="800"]] 208 + 209 +In this section: 210 + 211 +* Online – a flag of normal communication with the inverter; 212 + 213 +=== ASTOM load bank (cycling) === 214 + 215 +Information about the status of communication with a ASTOM load bank is available in the "External equipment → Inverters → ASTOM load bank (cycling)" section: 216 + 217 +[[image:1740651484968-315.png]] 218 + 219 +In this section: 220 + 221 +* Current state – current state of the cycle algorithm; 222 +* Time elapsed, second; 223 +* Number of completed cycles; 224 +* Load bank online; 225 +* Load current, A; 226 +* Input voltage, V; 227 +* Maximim DOD – maximum measured DOD during cycling, Ah; 228 +* Logic index – BMS Logic identifier with fastest discharging cell connected; 229 +* Cell index – number of fastest discharging cell; 230 +* Start cycling – a trigger to start cycling. 231 + 195 195 === HYG Class I-III truck === 196 196 197 197 Information about the status of communication with a HYG Class I-III truck is available in the "External equipment → Trucks and Vehicles → HYG Class I-III truck" section:
- 1740651146561-123.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.5 KB - Content
- 1740651353463-581.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +11.1 KB - Content
- 1740651484968-315.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +25.8 KB - Content